(Refer To Typical System Installation Diagram)

INSTALLATION STEPS 

OPERATING THE CONTROLLER

Attach Wall Mounting Bracket in the desired location for the NKD-pH using the 

Wall Plugs and Mounting Screws provided.

Snap the pH Controller into the locating pins of the Mounting Bracket.

Install the Clear Injection Tee Piece before or after the OXI & ION Cell Housing 

taking note of the flow direction indicator. Note: This should be installed after 

any heating. 

Measure and cut the Clear Flexible PVC Tube for the Clear Injection Tee Piece.

Use the remaining Clear Flexible PVC Tube for the acid drum, keeping the acid 

drum a minimum of 2m from any equipment.

Drill a 6mm hole in the lid of the acid drum for the Clear PVC Flexible Tube and 

attach Acid Drum Label to the cap.

Connect the Clear PVC Flexible Tube to the base of the peristaltic pump (left 

side) and feed through the 6mm hole into the acid drum and attach to the Acid 

Drum with weighted Suction Valve.

Connect the Clear Flexible PVC Tube to the base of the peristaltic pump (right 

side) and attach to the Clear Injection Tee Piece.

Plug the pH Controller cable into the programming plug on the base of the 

Naked Control Unit.

Plug the piggy back plug into the AC socket on the base of the Naked Control 

Unit and then the pump into the piggy back plug.

STEP 1

STEP 3

STEP 4
STEP 5

STEP 6

STEP 7

STEP 8

STEP 9

STEP 10

STEP 2

It is important to understand a certain amount of owner maintenance and care is 

required to keep your investment operating properly. We recommend the following 

basic maintenance and further information can be found on the Naked Pools App.

4.1 Injection Point on Injector Valve

Check the injection point periodically by inspecting the Clear Injection Tee Piece for 

build-up of solid matter at the end of the PVC tubing. While unscrewing the BLACK 

lock nut, take care not to lose the rubber O-ring.

4.2 Lubricate Squeeze Tube

Lubricate the pump squeeze tube every 3-6 months. Use a silicone-based lubricant 

only as petroleum-based lubricants will cause damage to the tube and rollers.

4.3 Replace Squeeze Tube

Depending on usage, the squeeze tube may need replacement after 1-2 years of use. 

Before replacing, ensure that the suction and injection tubes are empty. To replace 

the squeeze tube, please follow the instructions included with the replacement kit, 

or on the Naked Pools App. 
Only use original sized commercial grade Tygon® Norprene® tube as incorrect sizing 

will result in early failure of the Tri Roller Block.

The NKD-pH is based on an algorithm and is designed to dose acid into the pool 

each day based on a preset time in accordance with the pool size entered during the 

Initial Start-up. 
The pH controller will be activated each day when T1 starts and will run for the 

preset time based on the pool size.
If pH levels are high, longer running times will be required, and similarly if levels are 

low, run times will need to be decreased. Every swimming pool is different 

depending on the set up and environment. 
To change dosing times simply press [OK] for the Main Menu within the Naked 

Control Unit and using the [+] and [-] buttons select M15 pH Control.

Содержание NKD-pH

Страница 1: ...ALLATION IMPROPER INSTALLATION WILL VOID WARRANTY PRODUCT ONLY TO BE INSTALLED SERVICED BY A SUITABLY QUALIFIED PROFESSIONAL THIS MANUAL CONTAINS IMPORTANT INFORMATION ONCE INSTALLATION IS COMPLETE IN...

Страница 2: ...ts There is a danger of electric shock if opened If the power cord is damaged then the manufacturer their agent or a similar qualified person in order to avoid a hazard should replace it The product s...

Страница 3: ...ad Screwdriver PVC Primer Glue Drill 6mm Drill Bit pH Controller with Wall Mount Bracket Clear Tee with Lock Nut Injector Valve c w Sleeve Tube Nut Injector O Ring Clear PVC Flexible Tube 6m Acid Drum...

Страница 4: ...the OXI ION Cell Housing taking note of the flow direction indicator All installations must be after any heating Store the acid drum at the furthest possible point away from all equipment Before you s...

Страница 5: ...tach to the Acid Drum with weighted Suction Valve Connect the Clear Flexible PVC Tube to the base of the peristaltic pump right side and attach to the Clear Injection Tee Piece Plug the pH Controller...

Страница 6: ...nt entered and once completed will return to the RUN TIME in pH1 Calculate the amount of acid required by using the Dosing Calculator in the Naked Pools App Simply select the ml required by pressing t...

Страница 7: ...Tube Heavy duty PVC Approved piggy back type 40 50mm 80 650 34 2 5 4 2 Lubricate Squeeze Tube Lubricate the pump squeeze tube every 3 6 months Use a silicone based lubricant only as petroleum based l...

Страница 8: ...Swimming as nature intended or visit your App Store and search Naked Pools 1800 625 331 support naked pools com www naked pools com SCAN THIS CODE T O G E T T H E NAKED APP...

Отзывы: