7
TECHNICAL SPECIFICATIONS
Volts Input (Vac)
Amps Input - Max. (Aac)
Total Power Consumption (W)
Frequency (Hz)
pH Controller Dimensions (mm)
Output Controlled by Sanitiser (LPH)
Rated Pressure (kPa)
Squeeze Tube
Motor Speed (RPM)
Non-Return Injector Valve
Tubing
Roller Block
Power Cord
Water Connection
Water Flow Rate (L/min)
IP Rating
Net Weight (kg)
220-245
1.00
13W Motor - 20W Total
50
135W x 225H x 123D
0-1.0
350
Tygon® Norprene® (Commercial spec)
10
PVC with viton sleeve
6m x 6mm Clear Flexible PVC Tube
Heavy-duty PVC
Approved piggy-back type
40/50mm
80-650
34
2.5
It is important to understand a certain amount of owner maintenance and care is
required to keep your investment operating properly. We recommend the following
basic maintenance and further information can be found on the Naked Pools App.
4.1 Injection Point on Injector Valve
Check the injection point periodically by inspecting the Clear Injection Tee Piece for
build-up of solid matter at the end of the PVC tubing. While unscrewing the BLACK
lock nut, take care not to lose the rubber O-ring.
4.2 Lubricate Squeeze Tube
Lubricate the pump squeeze tube every 3-6 months. Use a silicone-based lubricant
only as petroleum-based lubricants will cause damage to the tube and rollers.
4.3 Replace Squeeze Tube
Depending on usage, the squeeze tube may need replacement after 1-2 years of use.
Before replacing, ensure that the suction and injection tubes are empty. To replace
the squeeze tube, please follow the instructions included with the replacement kit,
or on the Naked Pools App.
Only use original sized commercial grade Tygon® Norprene® tube as incorrect sizing
will result in early failure of the Tri Roller Block.