14
Lever
ON (Open)
OFF (Close)
Fig. 4
8 - 4 ON / OFF Valve (Fig. 4)
Turn the ON / OFF Lever located on the valve 90-Degrees
to turn the air output ON (Open) or OFF (Close).
9
. INSTALLATION AND CONNECTION OF THE AIR LINE KIT
CAUTION
The Air Line Kit install to the horizontal. If " Rear Mounting ", install the Air Line Kit to the
horizontally on a vertical wall.
9 - 1 Installation of the Air Line Kit
(1) Horizontal Installation
When the Air Line Kit is mounted from the bottom in a horizontal position Af
¿
x the Rubber Pads
(Standard Accessories : 4pcs.) to the bottom of the Air Line Kit.
(2) Rear Mounting or Bottom Mounting
Attach the Air Line Kit by the Mounting Screws (Cross-Recessed Truss Tapping Screw : M6
×
20)
(Standard Accessories : 4pcs) or M6 screw (not included / provided by the end-user) (Fig . 5).
* When Rear Mounting, attach using the Washers (Standard Accessories : 4pcs) between mounting surface
and rear surface of the Base Plate with on horizontal attitude.
20
190
Bottom Mounting
Rear Mounting
20
30
70
20
4 -
ȭ
7
220
20
190
20
20
170
30
2 -
ȭ
7
10
ȭ
15
R3.5
Base Plate
Fig. 5