10
CAUTION
①
Use of dry air
Using compressed air containing excessive moisture could result in malfunction or failure of
the spindle and motor. If excessive moisture or condensation are found in Air Filter Bowl, it
will be necessary to install a dryer and larger Air Filter on the primary side of the Air Line Kit to
prevent and remove excessive moisture.
②
Draining
Be sure to drain moisture and condensation from Air Filter Bowl regularly to avoid moisture
being carried to the spindle and motor.
③
Installation Location
Place this Air Line Kit on a
À
at and level surface.
If mounting on a wall, check if the wall is
À
at, and securely mount the Air Line Kit in a
horizontal direction.
④
Handling
When removing the Bowl for cleaning, carefully remove them as not to cause damage to them.
CAUTIONS for STORAGE, INSTALLATION and OPERATION
①
Do not use the Air Line Kit where corrosive gasses, chemicals, seawater, water, oils or steam exist.
②
Do not place in direct sunlight.
③
Do not use where the Air Line Kit is subject to vibration or repetitive shock.
④
Do not use where a heat source or radiated heat exist.
⑤
To conform to "STORAGE, INSTALLATION and OPERATION" (Refer to " 6. SPECIFICATIONS ").
When opening the package, check if it includes all items listed in " Table. 1 Packing List Contents ".
In the event of any shortage, please contact either NAKANISHI (see the " 4. CONTACT US " section) or your local dealer.
2
. BASIC PACKAGE
Table.
1 Packing List Contents
AL - C1204
・・
1pc.
Connection Hose (2m)
・・
1pc.
Rubber Pads
・・
4pcs.
Mounting Screws
(Cross-Recessed Truss Tapping
Screw : M6 x 20)
・・
4pcs.
Washers
・・
4pcs.
Hose Band
・・
1pc.
CKD Instruction Manual
・・
1set
Operation Manual
・・
1set
ྲྀᢅὀព᭩
INSTRUCTION MANUAL
CKD
ྲྀᢅㄝ᫂᭩
OPERATION MANUAL