background image

9

English

1

. CAUTIONS FOR HANDLING AND OPERATION

 Read these warnings and cautions carefully and only use in the manner intended.

 These warnings and cautions are intended to avoid potential hazards that could result in personal injury to the 

operator or damage to the device. These are classi

¿

ed as follows in accordance with the seriousness of the risk

.

Class

Degree of Risk

WARNING

A safety hazard could result in bodily injury or damage to the device if 
the safety instructions are not properly followed.

 

CAUTION

A hazard that could result in light or moderate bodily injury or damage to 
the device if the safety instructions are not followed.

WARNING

Handling
Connection to the Air Line Kit should be performed by a person with experience with 
compressed air and air compressors.

Air Pressure
Compressed air is required. Do not exceed an air pressure of 1.0MPa (145psi) at primary side 
and 0.85MPa (123.3psi) at secondary side of the Air Line Kit.

Use of Clean Air
Do not use compressed air contaminated with chemicals, oil compounds, organic solvents, 
salinity or corrosive gasses in order to avoid damage to the device.

Connection of connection hose and supply air hose
Connect the input connection hose and supply air hose securely to avoid accidental 
disconnection during use. Input air pressure should never exceed 1.0MPa (145psi).
Pressure exceeding 1.0MPa (145psi) may cause the connection hose and supply air hose to 
rupture.

Inlet and Outlet Connections
Do not hit, impact or cause shock to the Inlet or Outlet Connector Connections. Never put undo 
stress or load on the Inlet or Outlet Connector Connections. Any damage to these components 
can cause air leakage and the inability of the inlet or outlet quick disconnect to adequately 
secure the connection hose and supply air hose.

Mounting the Air Line Kit
When installing the Air Line Kit, securely install the Air Line Kit by mounting it on a 

À

at, level 

surface. If the Air Line Kit is dropped, damage to the Air Line Kit and injury to the operator is 
possible. 

Air Regulator Bowl

The bowl is made of a polycarbonate.
Do not use the Air Line Kit in conditions where chemicals or organic solvents  are present in 
the atmosphere.

 Do not remove the bowl guard. Using the Air Line Kit without the bowl guard may cause 
injury to the operator should the bowl burst. 

 When removing the bowl from the regulator, remove all pressure from the Input and Output 
sides of the Air Line Kit.

Thank you for purchasing the "AL - C1204" Air Line Kit. This Air Line Kit will supply clean and dry cooling air to the 
motor and spindle. THIS AIR LINE KIT IS NOT A SUBSTITUTE FOR AN AIR DRYER.
Read this and all the associated component Operation Manuals carefully before use. Always keep this Operation 
Manual in a place where a user can referred to for reference at any time.

Содержание AL -C1204

Страница 1: ...取 扱 説 明 書 OPERATION MANUAL 日本語 P1 P7 English P9 P15 1 AL C1204 エアーラインキット Air Line Kit OM K0653 001 ...

Страница 2: ... should never exceed 1 0MPa 145psi Pressure exceeding 1 0MPa 145psi may cause the connection hose and supply air hose to rupture Inlet and Outlet Connections Do not hit impact or cause shock to the Inlet or Outlet Connector Connections Never put undo stress or load on the Inlet or Outlet Connector Connections Any damage to these components can cause air leakage and the inability of the inlet or ou...

Страница 3: ...lly remove them as not to cause damage to them CAUTIONS for STORAGE INSTALLATION and OPERATION Do not use the Air Line Kit where corrosive gasses chemicals seawater water oils or steam exist Do not place in direct sunlight Do not use where the Air Line Kit is subject to vibration or repetitive shock Do not use where a heat source or radiated heat exist To conform to STORAGE INSTALLATION and OPERAT...

Страница 4: ...s Hours U S Toll Free No Telephone No Fax No Web Address Industrial Div 8 30am to 17 00pm CST closed Saturday Sunday and Public Holidays 800 585 4675 847 843 7664 847 843 7622 www nskamericacorp com Contact Us Contact Us For U S Market Company Name Business Hours Telephone No e mail Address 8 00am to 17 00pm closed Saturday Sunday and Public Holidays 81 0 289 64 3520 webmaster ie nsk nakanishi co ...

Страница 5: ... Air Pressure Drop 0 01MPa 1 5psi Drain Reservoir Capacity 80cm3 Safe Pressure Regulator Operating Range 0 05 0 85MPa 7 3 123 3psi Pressure Relief Automatic Relief Valve Dimensions W230mm D120 mm H220mm Weight 1 9Kg Operation Environment Temperature 5 40 C Humidity MAX 85 Atmospheric pressure 700 1 060 hPa Transpotation and Storage Environment Temperature 10 60 C Humidity 10 80 Atmospheric pressur...

Страница 6: ...ig 3 The water dirt and debris are separated from the compressed air The separated debris is collected in the Bowl 8 2 Draining Fig 2 To divert the drain to another location Connect a hose with a ȭ6mm I D Not included provided by the end user to the Drain Output Port and divert to another location Opening and closing the Drain Valve DO NOT allow liquids and or debris to exceed the Upper Limit as s...

Страница 7: ...ine Kit is mounted from the bottom in a horizontal position Af x the Rubber Pads Standard Accessories 4pcs to the bottom of the Air Line Kit 2 Rear Mounting or Bottom Mounting Attach the Air Line Kit by the Mounting Screws Cross Recessed Truss Tapping Screw M6 20 Standard Accessories 4pcs or M6 screw not included provided by the end user Fig 5 When Rear Mounting attach using the Washers Standard A...

Страница 8: ...ose and supply air hose Replace the connection hose and supply air hose No air Àow Check the compressor power supply and the air compressor output Check if connection hose and supply air hose is broken bent or disconnected Check the Regulator and set to the correct air pressure Check all connection hose and supply air hose connections ON OFF valve is OFF position The ON OFF valve set to ON positio...

Страница 9: ...2016 04 18 005 ...