© Ernst Nagel GmbH 9965043 Operations manual Foldnak 80-100 Trimmer 100.doc Rev.1.3 23.10.2006 25
Service
It is possible to check every actuator and sensor from the service submenu.
Submenu Foldnak Actuators
Description
Connector
on PCB
Pins Signal
FA1
SOLENOID
Solenoid Staple stop
J18
1: GND; 5: 24 V
FA2
MAIN MOTOR
Main motor via SSR
J18
2: GND; 6: 24 V
FA3
STAPLE
Clutch CB6 Stapling
J18
3: GND; 7: 24 V
FA4
FOLD
Clutch CB5 Folding
J18
4: GND; 8: 24 V
FA5
AUX1 ERR S8
Error FK at S8
J19
1: GND; 9: 24 V
FA6
AUX2
Input sensor at S8
J19
2: GND; 10: 24 V
FA7
AUX3
Trimmer error at S8
J19
3: GND; 11: 24 V
FA8
AUX4
--
J19
FA9
AUX5
--
J19
FA10 AUX6
--
J19
FA11 AUX7
--
J19
FA12 DELIVERY
Delivery
J19
8: GND; 16: 24 V
FA13 RELAY 1
FA14 RELAY 2
FA15 ERROR LED
Error LED
J20
1: GND; 2: 3 V
FA16 GREEN LED
Error LED
J20
3: GND; 4: 3 V
FA17 LED3
Error LED
J20
5: GND; 6: 3 V
FA18 LED4
Error LED
J20
7: GND; 8: 3 V
FA19 LED5
Error LED
J20
9: GND; 10: 3 V
FA20 LED6
Error LED
J20
11: GND; 12: 3 V
FA21 LED7
Error LED
J20
13: GND; 14: 3 V
FA22 LED8
Error LED
J20
15: GND; 16: 3 V
FA23 FINGER FORW.
FA24 FINGER BACKW.
1, 11 coil 1; 2, 12 coil 2
FA25 SIDEGUIDE CLOSE
FA26 SIDEGUIDE OPEN
3, 13 coil 1; 4, 14 coil 2
FA27 STAPLEPOS CLOSE
FA28 STAPLE POS OPEN
5, 15 coil 1; 6, 16 coil 2
FA29 FOLD POS CLOSE
FA30 FOLD POS OPEN
7, 17 coil 1; 8, 18 coil 2
FA31 ENDURANCE RUN
Continuous run
--
GND = Ground
SSR = Solid state relay
Содержание Foldnak 100
Страница 1: ...Foldnak 80 100 Trimmer 100 Operations manual Service instruction ENGLISH ...
Страница 31: ... Ernst Nagel GmbH 9965043 Operations manual Foldnak 80 100 Trimmer 100 doc Rev 1 3 23 10 2006 31 ...
Страница 32: ... Ernst Nagel GmbH 9965043 Operations manual Foldnak 80 100 Trimmer 100 doc Rev 1 3 23 10 2006 32 ...
Страница 33: ... Ernst Nagel GmbH 9965043 Operations manual Foldnak 80 100 Trimmer 100 doc Rev 1 3 23 10 2006 33 ...