4 of 35
Opus Control Wiring and Programming Installation Manual
www.NabcoEntrances.com
P/N C-00139
Rev 3-9-18
CHAPTER 2: SCOPE
SECTION 2.1: To the Installer
The purpose of this manual is to familiarize the installer with the proper installation and operation of this system. It is essential
that this equipment be properly installed and operational before the door is used by the public. It is the installer’s responsibility
to inspect the operation of the entrance system to be sure it complies with any applicable standards. In the United States, ANSI
Standard 156.10 (Used to cover Full Energy doors) and ANSI Standard 156.19 (Used to cover Low Energy doors) apply. Other local
standards or codes may apply. Use them in addition to the ANSI standards.
The owner should determine the door is operating properly and should immediately call for service if there is any malfunction. All
installation changes and adjustments must be made by qualified, NABCO trained technicians.
If after troubleshooting a problem, a satisfactory solution cannot be achieved, please call Nabco Entrances at 1-877-622-2694
between 8 am – 4:30 pm Central time for additional assistance.
SECTION 2.2: Objective
The Opus Control is designed to be installed within the Header of:
X
X
New Swing and Folding Doors.
X
X
Existing swing and folding doors using Analog, Magnum, or U01-U19 controls (works with encoders or
microswitches).
X
X
Existing sliding doors using U01-U19 controls. Retrofit kits can be purchased by contacting Customer Service at
1-888-679-3319.
This manual offers step by step instructions. Do Not take shortcuts.
CHAPTER 3: FEATURES
Specification
Description
Power Close
Built-in
Back Check Angle Adjustment
►
►
5 to 35 degrees from Full Open position
►
►
Used with Encoder Motor only.
Latch Check Angle Adjustment
►
►
10 to 40 degrees from Full Closed position
►
►
Used with Encoder Motor only.
Built In Sequencer
Can activate:
►
►
Electric Locks
►
►
Electric Strikes
►
►
Electric Latch Retracted Panic Devices
CHAPTER 4: SPECIFICATIONS
SECTION 4.1 General Specifications
Specification
Description
Temperature Range
-13 degrees to 140 degrees Fahrenheit
Motor Type
DC Brush Motor with Encoder, 115V
Number of Signal Inputs
►
►
1 x Activation
►
►
2 x Door Mode
►
►
2 x Safety
►
►
1 x Sequential
►
►
1 x Breakout (stop)
►
►
2 x Programmable
Number of Outputs
►
►
1 x Electric Lock Form C Relay
►
►
2 x Programmable Transistor Outputs