ElectricalInstallationManualU-30“D”Control
www.NabcoEntrances.com
Part #C-00121
Rev. 8-25-16
8-30
CustomWiring
Section 8d: 12 VDC Relay Assembly
12VDC-COMMO
N
Auxiliary Output (Open-Collector)
Sequential Activatio
n
5Amax.(0-20V), 3.2Amax.(20-30V) 30V(42.4Vpeak)max. Contact Output (Class2 Load only
)
FUNCTION [SLIDING DOOR
]
REDUCED OPENING SWITCH
Breakout Detector
Sidelite Presence Sensor
Exterior Activatio
n
HOLDING BEAM INTERIOR ACTIVATIO
N
12VDC-(COMMON) 12VDC+
Mode Switch (see Mode SW Usage shown left
)
Commo
n
N/
C
N/
O
SQ
OU
T
OUT.
A
OUT.
B
OUT.
C
7
SYMBO
L
BA
62
SL
S
M1
H
M0
6B
9DC12V
7
61
12
13
14
15
16
No
.
11 10 9 8 7 6 5 4 3 2 1
RELATED DEVICES - 16P
NOTE
:
1.
OTHER WIRES NOT SHOWN FOR SIMPLICITY
USING THE HANDY TERMINAL, SET "EXTRA FUNCTION ADJUSTMENTS/AUXILIARY OUTPUT
2"
AS SHOWN BELO
W
Auxiliary Output 2 - Message will read FUNCTION(23)
3
Determines when the relay connected to Terminal 15 (BRN/YEL) and Terminal 1 (BRN) turns on
.
The following (7) options are available:
Zero
=
Signal at Full Open - relay will turn ON at the full open position
.
One
=
Air Lock Option In a passageway situation, Option (1) instructs the relay to turn ON to prevent a second Slide door from opening before the first Slide door reaches the fully closed position. Note: if
second door is another Nabco sliding door then relay is not required.
Two
=
Sequential Door Operation Instructs the relay to turn ON thereby sequentially activating a second Slide door for a se
t
time period. This requires adjusting "Output Timer 2" to select the time delay between the first and second door operations. Note: if second door is another Nabco sliding door then relay is
not required.
Three =
Signal at Full Closed Relay will turn ON to indicate the Slide door has reached a fully closed position
.
Four
=B
reak Away
The relay will turn ON if the door is broken out.
Five
=B
reak Away or Door Open Conditio
n
Relay will turn ON if
:
1.
Slide door is broken out ~ or
~
2.
Slide door is not fully closed
Six
=E
rror Detection
Relay will turn ON if the U30 Microprocessor Control detects any error except Error 5.
Seven=
No Output
Relay Specifications
:
Relay & Socket Assembly: .......... P/N 1412439 Contact arrangement:…………… Double Pole Double Throw (DPDT) - Form
C
Coil Voltage: ...............................
12 VD
C
Coil Current Draw: ...................... 47
mA
Max. switching current: ............... 5
A
Max. switching voltage:............... 250V AC, 30V DC Max. switching power: ................ 1,250 VA, 150
W
Coil Nominal operating power: .... 0.53W 0.9V
A
COM - Commo
n
N.O. - Normally Open N.C. - Normally Closed (as defined when relay is un-powered
)
TERMINAL BL
OCK ON U30 CONTROL
12 VDC RELA
Y ASSEMBL
Y
PA
RT NUMBER 14-12439 (INC
LU
DES RELA
Y AND MOUNTING SOCKET
TO MONIT
ORING
SYSTEM
COM
6
N.
O.
5
3 CO
M
4 N.
O.
2 N.
O.
1 COIL
COIL
8
N.
O.
7
DN 1371