![Nabco GYRO TECH GT-1175 Скачать руководство пользователя страница 25](http://html2.mh-extra.com/html/nabco/gyro-tech-gt-1175/gyro-tech-gt-1175_installation-manual_3086739025.webp)
Rev. 8-25-16
Part #C-00121
www.NabcoEntrances.com
ElectricalInstallationManualU-30“D”Control
ElectricLockWiring
7-23
CHAPTER 7: ELECTRIC LOCK WIRING
Note: Electric Locks can not prevent Breakout. If preventing Breakout is deemed necessary, panic
hardware must be fitted to the Door Panels.
The Electric Lock is optional and can come in (1 of 2) configurations:
►
►
Fail Safe
•
Allows the Door Panel to be manually opened if power is turned Off.
►
►
Fail Secure
•
Will not allow the Door Panal to be manually opened if power is turned Off.
Electric Locks are used to prevent Door Panels from opening until they are activated by the U30
Microprocessor Control when it receives a signal from a:
►
►
Remote Switch
►
►
Transmitter
►
►
Activation Device on the face of the Door
Electric Locks are pre-installed at the NABCO Factory. Only the Strike mounted on the Header may
need to be adjusted.
Section 7a: Adjust the Strike.
1.►
Close Door Panel(s).
2.►Go inside the Header. Loosen the Strike Mounting Bolts that is holding the Strike Bracket
secure to the Header.
3.►Slide the Strike to align with the Latch Bolt in the fully closed position.
4.►Tighten the Strike Mounting Bolts.
a. Do not overtighten.
Figure 7-1
Adjust the Strike
DN 1026
Electric Lock Assembly
LATCHBOLT POSITION:
• BIPART UNITS
• LH SINGLE F.O.
• RH SINGLE F.S.
LATCHBOLT POSITION:
• RH SINGLE F.O.
• LH SINGLE F.S.
Dead Bolt Assembly
Belt Clip
Electric Strike
Dead Bolt Engaged with Electric Strike
(Door in Full Closed Posi on)
Slight Gap
(Between Strike Wall
and Dead Bolt)
Terminal Strip
(Strike Side of Door)
Содержание GYRO TECH GT-1175
Страница 2: ...THIS PAGE IS INTENTIONALLY LEFT BLANK...