![Nabco GYRO TECH GT-1175 Скачать руководство пользователя страница 15](http://html2.mh-extra.com/html/nabco/gyro-tech-gt-1175/gyro-tech-gt-1175_installation-manual_3086739015.webp)
Rev. 8-25-16
Part #C-00121
www.NabcoEntrances.com
ElectricalInstallationManualU-30“D”Control
IdentifyOperatingWires
4-13
Rocker Switch
Mode
Key Switch
Mode
Wire
M0
Wire
M1
Wire
H
Description
One Way
Exit
ON
OFF
-
X
Sensor on Terminal (3) can open the door.
• Sensor is normally Interior and used to activate door
for one-way traffic.
X
Sensor on Terminal (8) can not open the door from the
closed position.
• Sensor is normally Exterior and used to provide
threshold safety only.
•
Electric Lock remains locked unless an activation
occurs from the interior sensor or by a device (such
as a card reader, key switch, wall plate, etc.) that is
connected in one of two ways:
1.►Between Common and M1 (6)
a.►This only works when door is in “One Way” or
“Exit” mode.
2.►Between Common and SLS (11)
a.►This only works if the SLS is programmed for
activation devices.
Note: Consult the U30 Programming Manual for details;
(P/N 15-9000-30).
Full Open
Full
-
-
OFF
X
Upon activation or in Hold Open mode, Slide door will
open to the full position.
Reduced Open
Reduced
-
-
ON
X
Upon activation, Slide door will open to the Reduced
Open position.