Do not place finger or uninsulated tools inside the electrical GT20 Control . Touching wires or
other parts inside the enclosure may cause electrical shock, serious injury or death .
1. Ensure the Power is OFF.
2. Use a T-10 Torx Allen Wrench to remove (4) M3 x 5 Torx Screws used to secure the GT20 Control Board. Set Aside. Figure 4.
a. The (4) Torx screws are located at (2) corners on the opposite side of the Terminal Strips and (2) middle location on the
opposite side of the Relay PCB Board Connector Strip.
3. Insert (4) M3 x 12 Stand Off Torx Screws within each screw hole.
4. Secure the Relay PCB Board onto the GT20 Control with (4) M3 x 5 Torx Screws.
5. Proceed to wire each PCB Terminal accordingly.
SECTION 11 .2: Program the Relay PCB Board
1. Switch-on the Main Power Switch. The Home Page will be displayed.
>##<
E01
2. Briefly push down on the Joystick. The Menu Selection Page will be displayed.
3. Move the Joystick to the Right or Left until the Menu CONFIG is displayed.
CONFIG
4. Briefly push down on the Joystick. An Element Page will be displayed.
5. Move the Joystick Down until the Element RC 0.1 is displayed.
RC 0.1
CLOSED
6. Briefly push down on the Joystick. The Value will start to blink on the lower half of the screen.
7. Move the Joystick to the Right or to the Left to select(1) the appropriate Value.
8. Repeat steps 5 thru 7 until all Relay PCBs are programmed within the GT20 Control.
11 .2 .3 Configuration Menu for Relay PCB Board
RC 0.1
RC 0.2
RC 0.3
RC 0.4
CLOSED
OPEN
ERROR
GONG
Only (1) PCB Terminal per Switch Activation is allowed. For example (2) activations (during closing and
opening) must be wired to (2) different PCB Terminals.
Note: The Configurator Menu will only display the following Elements/Values when the Relay PCB
Board is intalled.
Note: NABCO does not install more than (1) Relay PCB Board.
CLOSED
Relay switches when the Door Panel is fully closed.
OPENNG
Relay switches when the Door Panel is opening.
OPEN
Relay switches when the Door Panel is fully open.
CLOSING
Relay switches when the Door Panel is closing.
ERROR
Relay switches if the GT20 Control detects an Error(s).
PSAUTO
Relay switches when the Program Selector is in Mode: AUTOMATIC
PSNIGHT
Relay switches when the Program Selector is in Mode: NIGHT
PSEXIT
Relay switches when the Program Selector is in Mode: EXIT
PSOPEN
Relay switches when the Program Selector is in Mode: OPEN
PSMANU
Relay switches when the Program Selector is in Mode: MANUAL
GONG
Relay switches
momentarily
during the time the GT20 Control recieves a signal from: Terminal
12 and Terminal 13 (Opening Command Inside).
LOCKED
Relay switches during the time the Door Panel is LOCKED with an electric lock.
DANGER