SECTION 10 .2: Safety Element Connections:
Safety Elements that are connected to their respective GT20 Controls:
X
(SER) Push side door mounted Sensor (for re-opening the door).
X
(SES) Pull side door mounted Sensor (for stopping the door).
SECTION 10 .3: EMY-IN Sensor Connections:
An active (EMY-IN) Emergency Input Signal Sensor connected to the:
X
Master Door Panel: Will force the Master Door Panel to open first and then the Slave Door Panel second.
X
Slave Door Panel: Will force the Slave Door Panel to open first and then the Master Door Panel second.
SECTION 10 .4: Electric Lock Connections:
An electric lock, that is connected to the:
X
Master Operator Assembly: Locks the Master Door Panel
X
Slave Operator Assembly: Locks the Slave Door Panel
SECTION 10 .5: Open/Close Settings
1. Select the Parameter: DubleD (Closing Sequence Role Master/Slave).Select the Setting Range:
X
MastrA:
To activate the Master Door Panel first.
X
SlaveA:
To activate the Slave Door Panel second.
a. If a CANbus connection exists between the GT20 Controls, the Master is identified by a small black (m) and the Slave
by a small black(s).
b. If a CANbus connection does not exist, the Master is identified by a small white (m); the Slave by a small white (s).
2. Select the Parameter: VO (Opening Speed).
3. Select the Setting Range: 0 - 14 seconds.
a. Each GT20 Control is independent from each other. It is possible to select a different setting range if deemed necessary.
For example: Master: Vo = 4 seconds; Slave: Vo = 5 seconds
4. Select the Parameter: AoSeq (Delay angle for Slave opening sequence control).
5. Select the Setting Range: 0 - 105 degrees.
a. The default AoSeq setting is 0 degrees.
b. AoSeq = the Slave will start to open after the Master exceeded the opening angle of 20 degrees.
c. Once the Slave starts to open - it is possible for the Slave to catch up with, and then pass the Master. If this is required,
select a higher VO Setting Range for the Slave Door Panel.
6. If an electric lock is installed on the Master, select the Parameter: TDelay (Time Delay).
7. Select the Setting Range: 0 - 4 seconds.
a. TDelay sets the amount of time the Master needs to hesitate in order to allow the electric lock to release before opening.
b. When the Setting Range for TDelay is set higher than 0 seconds, the AoSeq angle between the Slave and the Master is
increased. AoSeq must be reduced.
c. An AoSeq value of 0 degrees means that both Door Panels will simultaneously open (no opening delay is active).
8. Select the Parameter: AcSeq (Delay angle for Master closing sequence control).
9. Select the Setting Range: 0-105 degrees.
a. The default AcSeq setting is 0 degrees.
b. The Master will start to close after the Slave exceeded the closing angle of 20 degrees.
c. This advance guarantees the Master and Slave close in one smooth closing motion.
d. If the Master closing speed is set so the Master overtakes the Slave while closing, the Master will stop at the 20 degree
angle to allow the Slave to fully close first.