28 of 43
GT20 Wire and Programming Manual
www.NabcoEntrances.com
P/N C-00140
Rev 5-7-18
Element
Unit Type Default
Value
Description
FWind Full & Low
OFF
OFF
X
X
Obstacle detection optimized for exterior doors (wind loads).
X
X
Assuming that a gust of wind is not a hard obstacle which will stop the door,
the motor current will rise “slowly”. In this case the GT20 Control will provide
additional power to continue the door movement.
X
X
When FWind is turned ON, Nabco strongly recommends the use of door
mounted sensors to stop or re-open the door if an obstacle is detected during
the door cycle.
OPEN
CLOSE
BOTH
Fo
Full Power
4
0...9
X
X
Opening force (force open) when an obstacle is detected during Open/Close
cycle or both.
X
X
In standard mode Obstacle Detection can not be switched On/Off. It can be
adjusted with parameters “Fo” = Opening force (force open) and v “Fc” =
close force (force close). To make Obstacle Detection least sensitive: set both
parameters on max. (= step 9). To make Obstacle Detection most sensitive: set
both parameters on min. = 0 (caution this can allow the drive to react to small
changes in wind).
Low Energy
9
0...9
Fc
Full Power
4
0...9
Low Energy
9
0...9
Foh
Full & Low
4
0...9
Hold-open force (force open hold)
Fch
Full & Low
0.0A
0.0A...3.5A
X
X
Interlocking Force (force close hold): automatically programs FLock and FDelay
if these settings are set at 0.
X
X
If there is no electric lock and the Interlocking Force Fch is not adjusted, Error
14/02 will be displayed as a warning after the Teach1 procedure and the Door
Panel will endlessly re-open.
LowEn Low Energy
OFF
OFF
Door Panel is Full Power in both directions
ON
X
X
Door Panel is Low Energy in both directions
X
X
Door Panel is activated by a Knowing Act
Width
Full & Low
48
30...63
Door Panel width
Weight Full & Low
200
100...550 Door Panel height
Ao
Full & Low
95°
20°...190° Opening angle of the door (angle open)
Teach must be activated after this setting has been changed.
Rod
Full & Low
STD-PH
STD-PH
Outswing Arm and Arm Shoe
Push Function = Right Hand
Motor Cable Connector: X = Orange
SLI-PL
Inswing Arm with Track and Roller
Pull Function = Left Hand
Motor Cable Connector: Y = Green
SLI-PH
Outswing with Inswing Track and Roller Push Function = Right Hand
Motor Cable Connector: X = Orange
DO NOT USE
WIN-PH
Not Available
Not Available
DIR-PH
Outswing Arm and Track; Not Available
Push Function = Right Hand
Motor Cable Connector: X = Orange
DIR-PL
Outswing Arm and Track; Not Available
Pull Function = Left Hand
Motor Cable Connector: Y = Green
OHC-PH
Overhead Concealed
Push Function = Right Hand
Motor Cable Connector: X = Orange
OHC-PL
Overhead Concealed
Pull Function = Left Hand
Motor Cable Connector: Y = Green
Rod
Full & Low
STD-PH
X
X
If panic breakout latch is installed and the motor is plugged in backwards or the wrong arms
are chosen during programming, there is a possibility the door can burst open unexpectedly
towards the installer once TEACH mode is initiated.
X
X
Teach must be activated after this setting has been changed.