background image

 

 

Figure 3 until image is sharp. 

Diopter Adjustment 

 
NOTE:

 The Ocular (eyepiece) lens of the ATLAS is a fixed focus lens and does not require any 

adjustments.  It is

 

set to zero diopters and can be used while wearing prescription eyewear or 

contact lenses. 

Operating Modes and Menus 

 
ATLAS binocular has the following operating modes: 

 

Normal Mode

 

 
Normal Mode is used for observation with ATLAS.  When the user powers up the ATLAS 
thermal binocular, Normal Mode is the default setting for the system. 
 

Menu Mode

 

 
Menu Mode allows the user to conduct system configuration (choice of reticle, color, brightness, 
etc.) and review some of the s

ystem’s parameters (part number and software version). 

 

USB Mode 

 
ATLAS will enter USB Mode when it is connected to the USB port of a Personal Computer (PC) 
with an optional USB cable.  When ATLAS is connected to the USB port of a PC, its core 
electronics power up automatically, but the rest of the system remains off and there is no image 
displayed through eyepieces.  In this mode it is possible, using appropriate software on the PC, 
to download images to the PC from the ATLAS unit and delete them from the ATLAS memory. 
 

NOTE:

 It is possible to power up ATLAS using power from 

the computer’s USB port and start 

the ATLAS in Normal Mode.  In order to prevent ATLAS from going into USB Mode and, 
instead, power up in Normal Mode, press down and hold Power button while connecting ATLAS 
to the USB port.  In this case it is still possible to download images to PC and delete them from 
the ATLAS but image is visible through the eyepieces and device can be operated as normal. 
 
 

 

Содержание ATLAS

Страница 1: ..._________________________________________________________ 220 Reservoir Street Suite 26 Needham MA 02494 781 505 8360 OPERATOR S MANUAL Thermal Binocular ATLAS Revision 2 39 March 2017 2017 Copyright...

Страница 2: ...djustment 11 Operating Modes and Menus 11 ATLAS Control Switches 12 Normal Mode Description 13 Taking Photos 13 Zoom 13 Polarity 14 Contrast Enhancement CE Adjustment 14 Menu Mode Description 14 Navig...

Страница 3: ...dge 9 Figure 6 Inserting Batteries Into Batteries Cartridge 9 Figure 7 ATLAS Control Switches 10 Figure 8 ATLAS Control Switches 12 Figure 9 ATLAS Electrical Connector 19 Figure 10 Optional ATLAS Cabl...

Страница 4: ...etecting the long IR part of the spectrum 7 5 13 5 m and designed to meet the demands of security professionals nature enthusiasts sailors hunters and sportsmen alike ATLAS offers unsurpassed performa...

Страница 5: ...eries in pockets containing metal objects such as keys coins sharp tools etc Those objects can damage batteries and short circuit them Shorted batteries may become very hot and could potentially cause...

Страница 6: ...egardless of available ambient light Black Hot White Hot polarity selection Color Pallet Edge Detect mode Digital 2x and 4x zoom High resolution throughout the entire field of view Nitrogen purged in...

Страница 7: ...al 7 Vertical Focus Manual Detection man size target m 2250 60 Detection Probability Recognition man size target m 820 60 Recognition Probability Identification man size target m 430 60 Identification...

Страница 8: ...ATLAS Components Figure 3 ATLAS Front View Figure 4 ATLAS Rear View...

Страница 9: ...ies Operation Refer to Figures 3 and 4 to identify components Installing Batteries WARNINGS DO NOT MIX OLD AND NEW BATTERIES DO NOT MIX BRANDS OF BATTERIES DO NOT MIX DISPOSABLE AND RECHARGEABLE BATTE...

Страница 10: ...rward Unscrew the Battery Compartment Cover 4 that is holding the Batteries Cartridge Pull Battery Cartridge 2 from the Battery Compartment Cover 4 Install three CR123 batteries 3 as shown on Figure 6...

Страница 11: ...ny user input by briefly closing the shutter located between image sensor and objective lens The calibration in Blade mode occurs automatically when system determines that calibration is necessary but...

Страница 12: ...ll enter USB Mode when it is connected to the USB port of a Personal Computer PC with an optional USB cable When ATLAS is connected to the USB port of a PC its core electronics power up automatically...

Страница 13: ...ssed and released quickly This only works if Enable Photo in Normal Mode is set to YES in Settings 2 Digital Zoom Magnifying Glass Cycles digital zoom settings 1X 2X 4X 3 CE Cal Switch Increases the C...

Страница 14: ...the USB port of a PC all switches will function as in Normal Mode Normal Mode Description Normal Mode is used for observation with ATLAS When the user powers up ATLAS it always starts in Normal Mode F...

Страница 15: ...lgorithmically not important and outlines objects that produce distinctive heat signature This helps users stay focused for longer periods of time and quickly identify object of interest when it becom...

Страница 16: ...5 to decrease it To save the changed menu item press Switch 4 MENU Main Menu System Settings Under this submenu a user can change type of calibration choose format of the output video signal PAL or NT...

Страница 17: ...S to Scene calibration mode NOTE 3 Scene calibration mode does not occur automatically and requires user to perform it manually To do Scene calibration press and hold the Switch 3 CAL for approximatel...

Страница 18: ...polarity with Switch 4 MENU Polarity in Normal Mode NOTE Instead of an image ranging between black and white to represent different infrared emittance levels there is a false color option to instead...

Страница 19: ...away excess dirt and dust that may restrict the performance or damage moving and mating parts If needed the use of a highly diluted detergent solution is permissible Dry with a soft clean cloth or all...

Страница 20: ...ility to Power the ATLAS from external USB power source Conduct observation using remote monitor Record video input from the ATLAS Download images from the ATLAS to PC Figure 9 ATLAS Electrical Connec...

Страница 21: ...nation the output video is a 1 Volt peak to peak signal Video Out must be terminated in order to get a video signal Video GND output video ground reference not to be used for any other ground than vid...

Страница 22: ...ment for damage Replace battery or install correctly Tighten Battery Compartment Cover Flickering image or unit turns off under light impact Visually inspect Check for loose Battery Compartment Cover...

Страница 23: ...This page is intentionally left blank...

Отзывы: