18
Table 3–7 Settings in the Port Menu - Continued
stat <S|T| E | clear> [port]
Shows the counter readings
- of the frame length (
S
)
- of the frames (
T
)
- of the errors (
E
)
of the selected port.
The counters are reset with
clear
.
Examples:
show S 1,3-5
Shows the frame length of ports 1
and 3 through 5.
name <port > <string>
With this function, you can assign a
symbolic name (string) with a
length of up to 64 characters to
each 608MFX port. (To insert a
blank in a string, use the tilde (~)
instead of a blank.)
Example:
name 5 Management~Port
Assigns the symbolic name
Management Port to port 5 of the
608MFX.
Administrator only
status <E | D> [port]
Activate | Deactivate 608MFX
ports.
Deactivated 608MFX ports are
disabled for data exchange.
Administrator only
fd_flow <E | D> [port]
Enable | Disable full duplex flow
control.
Administrator only
This flow control is
effective when the
selected ports operate in
the full duplex mode
and when flow control
is activated in the
Switch menu.
autoneg <E | D> [port]
Enable | Disable autonegotiation.
Administrator only
Only the 10BASE T/
100BASE TX ports can
be switched to the
autonegotiation mode.
lock <E | D> [port]
Enable | Disable the Lock port
property.