5. MECHANICAL INSTALLATION
5.2 Post Bracket Position and A&B Dimensions
Determine the A and B dimension based on the opening angle provided in Table 1 to confirm the position where the post bracket will be mounted.
1.
To ensure that the motor does not touch the pillar, please define your C dimension using B-60 mm formula.
2.
For optimal mechanical advantage A and B dimension shall be equal or not differ by more than 40 mm.
NOTE:
Smaller A and B dimensions determine higher peripheral speed of the leaf. Higher differences between A and B dimensions cause greater speed and force variati-
ons during the gate opening and closing movement. It is always good practice to use all available travel of the operator.
All crushing points must be secured by an entrapment protection according to EU: EN 12453, EN 60335-2-103; GB (UK, NI): BS EN 12453, BS EN 60335-2-103.
5.1 Dimensions of Gate and Operator
830 (max.1150)
CHLA250EVC
Herewith you start mechanical installation of the gate operator.
CHLA250EVC
1.5 m
200 kg
2.0 m
150 kg
2.5 m
100 kg
60
80
22
Ø 8.5
100
60
20
7
125
92
133
Example installation
C
Gate
B
A
Gate Bracket
Gate Operator
Post Bracket
Gate Post
Extension bracket (not included)
B
A
Gate Bracket
Gate Operator
Post Bracket
Gate Post
Gate
CHLA250EVC with external hardstop,
using max 300 mm travel
mm
A
100
120
140
160
180
B
100
n.a.
110°
105°
105°
100°
120
110°
110°
100°
95°
95°
140
100°
100°
100°
90°
80°
160
95°
95°
90°
85°
75°
180
90°
90°
80°
75°
70°
Table 1:
Gate leaf bracket extension shall be co-
sidered in case the pivoting point of the
gate is not centered with the gate leaf.
85
33
24
70
50
90
11
0
Ø10