7.3 Wing Movement Direction
7.4 Basic Settings
Before programming, move the gate manually in the middle position and re-engage
release mechanism (see page 8).
Press and hold the “
–
“ button on the control board and ensure that the motors are
moving in
CLOSE
direction. If correct, immediately let go of the “-“ button and gate
stops.
If motors are moving in
OPEN
direction, go to the functions “
d1
“ and “
d2
” and
change the direction settings.
Once CLOSE direction is set correctly, leave the gate in the middle position. The
operator is ready for the Learning phase.
Note: gate can be moved with „ + “ and „ - „ buttons prior to final settings if required.
Press and hold the “
+
“ button on the control board to move the gate into
OPEN
position. When button is released operator stops.
Press and hold the “
–
“ button on the control board to move the gate into
CLOSE
position. When button is released operator stops.
Application function shown on display.
This function is already pre-set at factory at value 05.
More settings available on demand:
LED
Function
Basic Settings (mandatory)
AP
Application
d1
Direction Motor 1
d2
Direction Motor 2
LL
Limit Learning Phase
Basic Settings Overview
7.4.1 Application Settings
No application selected
Swing gate, one motor for CHLA250 application
Swing gate, two motors for CHLA250 application (defauft)
Direction Motor 1 function shown on display
Defines movement direction of the Motor 1.
7.4.2 Direction Motor 1 Settings
Motor 1 is moving in
closing
direction
Motor 1 is moving in
opening
direction
Direction Motor 2 function shown on display.
Defines movement direction
of the Motor 2. Not available for “one motor” application.
7.4.3 Direction Motor 2 Settings
Motor 2 is moving in
closing
direction
Motor 2 is moving in
opening
direction
Available Learning methods:
Before starting a Learning phase ensure that:
1. Other Basic Settings are completed
2. Internal / external hard stops are installed (for swing gates)
3. First movement will be in
CLOSE
direction.
1. Press and hold “
+
and
–
“ buttons for 2 seconds.
2. Automatic learning process starts.
LL
will flash on the display during complete
process.
3. Wing 2 moves in
CLOSE
direction until the hard stop is reached, and stops.
4. Wing 1 moves in
CLOSE
direction until the hard stop is reached, and stops for
2 seconds. Then Wing 1 starts in
OPEN
direction until the hard stop is reached.
5. Wing 2 moves in
OPEN
direction until hard stop is reached, stops for 2 seconds
and then moves in
CLOSE
direction until hard stop is reached, and stops.
6. Wing 1 moves in
CLOSE
direction until hard stop is reached, and stops.
7.
Standard Learning phase is finished. LL will appear on display and board will
return in stand-by mode after 3 seconds.
Standard Learning Mode (Automatic)
7.4.4 Limit Learning
P
+
S
2 sec.
III
III
3 sec.
P
+
S
Values 01-03 are not suitable for CHLA250 application and shall not be chosen.
NOTE
: In single motor application, “Wing 2” actions are not used.
Following settings are done during Standard Learning Mode:
1. Travel length from
FULL CLOSED
to
FULL OPEN
position.
2. Opening and closing force for each motor.
3. 15% of total travel in both directions is assigned for Soft Stop.
4. Wing delay in opening and closing position is 2 seconds. Shall you need to
change the delay please go to Advanced Settings: Delay Motor 2 (d0) and
Delay Motor 1 (dC).
7. PROGRAMMING