10. TECHNICAL DATA
CHLA250EVC
Input Voltage
VAC
220-240
Input frequency
Hz
50/60
Motor Voltage
VDC
24V
Standby consumption
(without accessories)
W
3.7
Motor Rated Power
(CHLA250EVC = 2 x CHLA250-24)
W
100
Rated Force
N
800
Maximum Motor Pushing/Pulling Force
N
1250
Cycles per hour
5
Max. cyles per day
20
Max. wing weight
m / kg
1.5m / 200kg
2m / 150kg
2.5m / 100Kg
Max. opening angle
110°
Time to open to 90°
s
15-18
Piston /Screw travel length
mm
300
Cable length
m
1.5
End Limit System
Encoder with hard stops
Operating Radio Frequency
Sending power
MHz
RX 433MHz (433.30MHz, 433.92MHz, 434.54MHz)
RX 868MHz (868.30MHz, 868.95MHz, 869.85MHz)
TX 865.125MHz, 865.829MHz, 866.587MHz
<10mW
Code
S 2.0
Max. nr of remotes
180
Max. nr. of keypads
4
Max. nr. of myQ devices
16
External accessory power
24VDC - max. 500mA
Flahing lamp connector
24VDC - max. 500mA
E-Lock /Magnetic lock conenctor
24VDC - max. 500mA
External relay
24VDC - max. 500mA
Safety edge
8,2 kOhm
Max. nr. of IRs
3
Max. nr. of external inputs
3
Battery back-up unit
2 x 12V, 2.2Ah SKU 490EV
Ingress protection Motor
IP
44
Ingress protection control board
IP
65
Noise Level
dB
< 70 db(A)
Working temperature
°C
-20°C to +55°C
Weight (kit)
Kg
19,6
Transmitter Frequency
TX4REV-F
868MHz (868.30MHz, 868.95MHz, 869.85MHz)
Sending power
<10mW
Battery