Glossary
Glossary-6
DAC960PG Installation Guide
☛
Note
The host operating system drivers and software
utilities remain unchanged regardless of the level of
RAID installed. The controller makes the physical
configuration and RAID level implementation
Replacement Table
A replacement table contains information regarding which SCSI devices
have been replaced by others through standby replacement.
Rotated XOR Redundancy
This term (also known as “parity”) refers to a method of providing complete
data redundancy while requiring only a fraction of the storage capacity of
mirroring. In a system configured under RAID 3 or RAID 5 (which require
at least three SCSI drives), all data and parity blocks are divided between the
drives in such a way that if any single drive is removed (or fails), the data on
it can be reconstructed using the data on the remaining drives. (XOR refers
to the Boolean “Exclusive-OR” operator.) In any RAID 3 or RAID 5 array,
the capacity allocated to redundancy is the equivalent of one drive.
SCSI Drive
A disk drive equipped with a SCSI interface (sometimes referred to as a
SCSI Disk). Each disk drive will be assigned a SCSI address (or SCSI ID),
which is a number from 0 to 7 (0 to 15 under Wide or Ultra SCSI). The SCSI
address uniquely identifies the drive on the SCSI bus or channel.
SCSI Drive States
Refers to a SCSI drive’s current operational status. At any given time, a
SCSI drive can be in one of five states: READY, ONLINE, STANDBY,
DEAD, or REBUILD.
The controller stores the state of the attached SCSI drives in its non-volatile
memory. This information is retained even after power-off. Hence, if a SCSI
disk is labeled DEAD in one session, it will stay in the DEAD state until a
change is made either by using a system level utility or after a rebuild. Each
of the states is described below:
Содержание DAC960PG
Страница 1: ...PCI RAID Controller Installation Guide DAC960PG PCI to Ultra SCSI P N 771971 D01...
Страница 2: ......
Страница 10: ......
Страница 24: ...DAC960PG Specifications 1 10 DAC960PG Installation Guide...
Страница 35: ...Functional Description Manual No 771971 2 11 Figure 2 4 Configuration on Disk Flowchart...
Страница 40: ...RAID Management 2 16 DAC960PG Installation Guide Figure 2 10 Block Striping with Parity RAID 5 standard...
Страница 48: ...Cache Management 2 24 DAC960PG Installation Guide...
Страница 58: ...SCSI Termination 3 10 DAC960PG Installation Guide Figure 3 3 Internal Disk Array Single ended SCSI Termination...
Страница 76: ...System Reboot or Power Down 4 10 DAC960PG Installation Guide...
Страница 78: ...SAF TE A 2 DAC960PG Installation Guide...
Страница 90: ...Battery Backup Capacity B 12 DAC960PG Installation Guide...
Страница 102: ...Glossary Glossary 12 DAC960PG Installation Guide...
Страница 105: ......
Страница 106: ......