Enable 8 GByte or 2 GByte Drives
This option can be toggled between 8 gigabyte and 2 GB drive geometries.
The default is 2 GB. This setting affects how the BIOS reads the disk drives.
The drive geometry must be set and then the drive must be formatted (or
reformatted).
The DAC960PG ships with the default BIOS geometry set to 2 GB. This
means that the BIOS will only be able to see the firsst 2 gigabytes of any
drive that has been configured on the DAC960PG. This is adequate in most
applications since BIOS is only used to boot the operating system.
However, it does mean the operating system must be installed somewhere in
the first 2 GB of the configured drive’s capacity. If for some reason this is
not adequate, the BIOS geometry can be changed to 8 GB. This will allow
the BIOS to see the first 8 GB of capacity.
m
Caution
If you have already configured your array and have
stored data, you should not change this setting.
Changing this setting after data has been stored will
have an effect similar to changing your stripe size. It
will make your stored data unreadable.
Error Messages
Start-up Error Messages
The BIOS also looks for any initialization message that may be posted by the
firmware during the start-up sequence. If it finds a message, it displays one
of the following errors on the screen and aborts the installation process.
DAC960PG fatal error--memory test failed
DAC960PG fatal error--command interface test failed
DAC960PG hardware error--run diagnostics to pinpoint error
DAC960PG firmware checksum error--reload firmware
Содержание DAC960PG
Страница 1: ...PCI RAID Controller Installation Guide DAC960PG PCI to Ultra SCSI P N 771971 D01...
Страница 2: ......
Страница 10: ......
Страница 24: ...DAC960PG Specifications 1 10 DAC960PG Installation Guide...
Страница 35: ...Functional Description Manual No 771971 2 11 Figure 2 4 Configuration on Disk Flowchart...
Страница 40: ...RAID Management 2 16 DAC960PG Installation Guide Figure 2 10 Block Striping with Parity RAID 5 standard...
Страница 48: ...Cache Management 2 24 DAC960PG Installation Guide...
Страница 58: ...SCSI Termination 3 10 DAC960PG Installation Guide Figure 3 3 Internal Disk Array Single ended SCSI Termination...
Страница 76: ...System Reboot or Power Down 4 10 DAC960PG Installation Guide...
Страница 78: ...SAF TE A 2 DAC960PG Installation Guide...
Страница 90: ...Battery Backup Capacity B 12 DAC960PG Installation Guide...
Страница 102: ...Glossary Glossary 12 DAC960PG Installation Guide...
Страница 105: ......
Страница 106: ......