Manual No. 771971
4-1
Chapter 4
Start-up Sequences
Introduction
This chapter describes the DAC960PG start-up procedures and messages
produced by the BIOS during start-up or re-boot. This chapter also explains
three BIOS options to be considered: BIOS enable/disable, CD-ROM boot
enable/disable, and a 2 or 8 Gigabyte Disk Drive Geometry setting.
The DAC960PG BIOS provides a single threaded interface to access up to
eight logical units (system drives) on each controller.
The Firmware 4.x BIOS presents physical drives to the host as large disk
drives with either 2 MB per cylinder or with 8 MB per cylinder. An
allowable number of up to 1024 cylinders allows a physical drive of up to
8GB to be accessed through the BIOS. An operating system specific driver is
required to access data beyond this limit.
Refer to the documentation for the DAC960 Software Kit for more
information on installing and using the various network operating system
drivers with the DAC960PG.
Instructions on using the DOS driver and creating a DOS-bootable disk are
located in the DACCF Configuration & Utilities diskette DOS subdirectory
in the file README.TXT.
System Power-Up Sequence
If the SCSI drives are powered up separately from the system, you should
always power up the SCSI drives before the host system. The drives and the
host system can power up simultaneously, as they would when there is a
common power switch for both.
BIOS Start-up Sequence
When invoked during power up, the BIOS will display a sign-on message
with its version number and date. The sign-on message looks similar to the
following:
DAC960 BIOS Version n.nn--
Содержание DAC960PG
Страница 1: ...PCI RAID Controller Installation Guide DAC960PG PCI to Ultra SCSI P N 771971 D01...
Страница 2: ......
Страница 10: ......
Страница 24: ...DAC960PG Specifications 1 10 DAC960PG Installation Guide...
Страница 35: ...Functional Description Manual No 771971 2 11 Figure 2 4 Configuration on Disk Flowchart...
Страница 40: ...RAID Management 2 16 DAC960PG Installation Guide Figure 2 10 Block Striping with Parity RAID 5 standard...
Страница 48: ...Cache Management 2 24 DAC960PG Installation Guide...
Страница 58: ...SCSI Termination 3 10 DAC960PG Installation Guide Figure 3 3 Internal Disk Array Single ended SCSI Termination...
Страница 76: ...System Reboot or Power Down 4 10 DAC960PG Installation Guide...
Страница 78: ...SAF TE A 2 DAC960PG Installation Guide...
Страница 90: ...Battery Backup Capacity B 12 DAC960PG Installation Guide...
Страница 102: ...Glossary Glossary 12 DAC960PG Installation Guide...
Страница 105: ......
Страница 106: ......