The MyGate Q71B Control Board Installation Manual : Printed 06/11/2012 14:25
23
Aerial - What does the extended aerial do and do I need one?
The extended aerial boosts the radio frequency capture range to 80m in all weather conditions. As the key-
fob remotes function by transmitting a radio frequency signal to the control board, signal quality can be
diminished as a result of poor weather. The improved signal capture range can also help for installations
where there is a long drive way to the gates or you need to open the gates much before you arrive.
Intercoms
– I have an intercom system, how do I connect it to my gate?
Power
Your intercom system may already be powered by separate source. If you are fitting a new intercom, the
Q71B control board has 12/24vdc power outputs available for fueling such equipment that requires
12/24vdc to function. Terminal 12 (power positive) and terminal 13 (power negative) provide the power
output. Check with your intercom install guide for suitability.
Opening the gate
Your intercom should have 2 sets of outputs for unlocking MAG locks (labeled as C
– Common & N/C -
Normally Closed) and for switching volt free contact equipment (labeled as C
– Common, N/O - Normally
Open). To connect the intercom to the Q71B control board for opening the gate from your intercom
handset:
Intercom
- Q71B Terminals
C (Common)
- 21
N/O (Normally Open) -
20
Digital Keypads
– I have a keypad for coded access, how do I connect it to my gate?
Power
Your digital keypad system may already be powered by separate source. If you are fitting a new digital
keypad, the Q71B control board has 12/24vdc power outputs available for fueling such equipment that
requires 12/24vdc to function. Terminal 12 (power positive) and terminal 13 (power negative) provide the
power output. Check with your digital keypad install guide for suitability.
Opening the gate
Your digital keypad should have 2 sets outputs for unlocking MAG locks on doors (labeled as C
– Common
& N/C - Normally Closed) and for switching volt free contact equipment (labeled as C
– Common, N/O -
Normally Open). To connect the digital keypad to the Q71B control board for opening the gate by entering
your pin code:
Intercom
- Q71B Terminals
C (Common)
- 21
N/O (Normally Open) -
20