Page
15
of
36
8.6
Relay & Sensor Board
eddi
has the option to install a Relay & Sensor Board (available separately). This allows for many different
wiring configurations and includes the following features:
Two independent multifunction relays (16 Amp)
eSense input (isolated 230V detection for economy tariff etc.)
Two temperature sensor inputs (PT1000)
The two relays can be independently set for several different functions, or they can be set to operate as a
pair. The relay functions include:
Export Threshold
Import Threshold
Operate when heating
De-stratification pump control
Timed operation
Fault signal for BMS systems
Refer to
Application Examples
in this guide for practical examples.
The Relay & Sensor Board is installed by plugging it into the
eddi
main circuit board using the three plastic
spacers included with the Relay & Sensor Board.
The flexible ribbon cable is then pushed into the black connector to the right-side of the display on the top
eddi
circuit board.