Page
33
of
36
10.8.1
Functional Description
In properties that benefit from a swimming pool,
eddi
can be used to maximise self-consumption of surplus
power, by first heating the domestic water before switching to divert the surplus power to contribute to pool
heating.
Heater 1 (the immersion heater in the hot water cylinder) (4) is heated with surplus power until the domestic
water is hot and the thermostat opens, then
eddi
will immediately switch over to Heater 2 to heat the pool (8)
with surplus power.
During heating of the pool (Heater 2),
eddi
will briefly switch back to the domestic water heater (Heater 1)
every 15 mins to check if it can store any more heat.
When Heater 2 is active (i.e.
eddi
is heating the pool), Relay 1 of the Relay & Sensor Board (6) will be on and so
the pool circulation pump (11) will run thus transferring heat from the pool heater (9) to the swimming pool.
Installation of the temperature probes (7) is optional; the heaters' mechanical thermostats are used by
eddi
if
temperature readings are not required.
10.8.2
Settings Required
Menu Option
Settings
Main
Menu
Settings…
Display… Icons… Heater 1:
Top
Immersion/Bottom
Immersion
Heater 2: Pool
Heater Settings
Priority…
Heater 1
Device
Settings
Advanced Relays &
Sensors
Temperatures…
Set Temperatures
as required if using
temperature
probes
Relay 1…
Heating
Heater 1
Содержание eddi 16A1P01H