IMPORTANT
Before turning on the water supply to the shower unit the water supply pipe should be flushed out to remove
debris. After flushing the pipework ensure that the shower unit is positioned squarely on the wall and tighten
the screws. Tighten all plumbing connections and check the pipework for leaks.
IMPORTANT
To comply with water regulations, building regulations or any specific local water company regulations and
should be in accordance with BS EN 806. A double check valve must be fitted with all flexible
shower accessories where it is possible that the showerhead may come into contact with used water
i.e. In the bath or shower tray.
!
!
!
!
!
!
!
!
dEFAULT PLUMBING SETTING
The shower unit is supplied for right hand
installation. To plumb the unit on the left you must:
1. Remove the bottom left hand side cover plate.
2. Carefully pull the metal retaining clip out of the
blanking end cap with a pair of pliers.
3. Slide off the blanking cap.
4. Refit the blanking cap on to the inlet pipe on the
right hand side of the unit.
5. Re insert the metal fixing clip ensuring it is
pushed primly into place.
IMPORTANT: When leak testing the installation
you must ensure there are no leaks from this area.
PLUMBING CONNECTIONS (CONT.)
The shower back plate incorporates into the lower
right and left hand side of the back plate removable
trim sections to allow easy access when deciding on
and connecting to the water mains supply.
Remove the bottom right hand side cover plate giving
access to the inlet spigot.
IMPORTANT: Before connecting the mains water
supply to the shower, flush out the pipe work to
remove all swarf and system debris. This is achieved
by connecting a hose to the pipe work and turning on
the mains water supply at the isolating stop tap long
enough to clear the debris to waste.
Turn off the mains water supply at the isolating
stop tap.
Having decided on the direction of the water inlet
supply: Top (falling) Bottom (rising) or Rear Inlet, it
is necessary to remove the appropriate knock out
(thinned out plastic) cross section from the back
plate before commencing with the installation.
The connection to the unit is made using a 15 mm
copper, stainless or plastic pipe with a 15 mm
compression elbow or 15 mm push fit elbow.
IMPORTANT: Do not use excessive force when
making the connection to the unit.
Tighten the back plate fixing screws so the unit is
firmly fixed to the wall.
If rear entry pipe work is used we recommend the use
of a suitable sealant to seal around the incoming pipe
work to prevent water entering the wall.
Turn on the mains water supply and check for leaks.
At this stage no water can flow through the unit.
IMPORTANT: Remember to replace the lower inlet
covers before refitting the front cover