18
COMMISSIONING THE SHOWER (CONT.)
PHASEd SHUT dOWN
The Phased Shut Down operation is activated when
the shower is stopped using the start / stop button.
It switches the heating elements OFF but allows the
water to run for approximately 6 seconds taking the
residual heat away from the elements and giving a
cool start up for the next user.
1. The seven segment display shows this operation by
counting down the horizontal bars 3 - 2 – 1 OFF
2. Switch off pull cord or wall mounted switch
IMPORTANT: When the shower is re-started it will
reach the temperature set by the last user as this has
been stored in the unit’s memory.
3. Finally we recommend that the shower head is
removed to make sure no debris has worked into it
and the inlet water filter is checked and cleaned of
any debris from the incoming pipe work. Clean and
re fit (see section 16 for cleaning instructions).
4. Make sure that the water supply is fully turned ON.
CAUTION
Always use the start / stop button to switch the shower OFF. If the pull cord or surface mounted isolator
is used to stop the shower without first pressing the start / stop button then you will by-pass the phased
shut down mechanism
!
!
!
!