14
10. CHANGING THE OPERATIONAL SHOWER PROGRAMMES
A four way dIP switch block is mounted on the main
power circuit board that allows the user to configure
certain shower functions. The settings can be
changed on installation by moving the control PCB
slider switches as described below.
The shower is supplied with:
• audible feedback ON (single bleep sounds on push
button command)
• automatic timed STOP feature set at the maximum
duration of 30 minutes.
NOTE: DIP switch is ON when slider switch in upper
position. DIP switch is OFF when slider switch is in
lower position.
Sound ON
slider switch 4 ON
Sound OFF
slider switch 4 OFF
Running Time 30 MINS
slider switch 1 OFF
slider switch 2 OFF
slider switch 3 OFF
Running Time 20 MINS
slider switch 1 ON
slider switch 2 OFF
slider switch 3 OFF
Running Time 10 MINS
slider switch 1 OFF
slider switch 2 ON
slider switch 3 OFF
Running Time 5 MINS
slider switch 1 OFF
slider switch 2 OFF
slider switch 3 ON
ON
DIP
1 2 3 4
SOUND
SWITCH
RUNNING
TIME
dEFAULT SETTINGS
Sound: ON
Running time: 30 MINS
ON
DIP
1 2 3 4
ON
DIP
1 2 3 4
ON
DIP
1 2 3 4
ON
DIP
1 2 3 4
ON
DIP
1 2 3 4
ON
DIP
1 2 3 4
ON
DIP
1 2 3 4
ON
DIP
1 2 3 4
ON
DIP
1 2 3 4
ON
DIP
1 2 3 4
ON
DIP
1 2 3 4
ON
DIP
1 2 3 4