14
Characteristics of the different types of gas
Burner
size
Gas type
Presure
mbar
Diámeter
of injector
Power
kW
Gas flow
Auxiliar
(Small)
Natural
G20/25
20-25
0.72
0,95
0,96 m³/h
Butane
G30
28-37
0.50
0,95
69 g/h
semi fast
(Medium)
Natural
G20/25
20-25
0.97
1,7
0,162 m³/h
Butane
G30
28-37
0.65
1,7
124 g/h
Fast
(large)
Natural
G20/25
20-25
1.40
2,9
0,333 m³/h
Butane
G30
28-37
0.96
2,9
254 g/h
CHANGING THE INJECTORS
To change the injectors, proceed as follows:
1.
Cut off or shut off the gas supply and unplug the gas hob from the electrical
outlet.
2.
Use a hex socket wrench of the appropriate stock to the injector head
(Figure 1).
3.
Remove the covers, as well as the burners of the four cooking zones to
access the injectors (Figure 2).
4.
Remove the injectors by turning the key counterclockwise. To insert the
injectors, do so with great care so as not to damage the threads and do not
tighten them with too much force as they could break (Figure 3).
Warning:
We recommend that this process be carried out by an authorized
installer, or by qualified personnel and/or authorized technicians.