9
Cooking zone control knobs do not rotate smoothly
Over time, gas control valves can become dirty from accumulated grease and
dust. In this case, it will be necessary to access the valves to clean and grease
them. This cleaning and greasing work must only be carried out by an
authorized Technician or the Official Technical Service.
Note:
If after these checks, you notice anomalies or that the gas hob does not work
properly, contact the Official Technical Assistance Service or consult an
Authorized Installer.
INSTALLING THE GAS HOB
Very important!
The installation of the gas hob must be carried out only by an authorized
installer.
MX ONDA
will not accept any responsibility and the guarantee will
be invalid in the event of an erroneous or incorrect installation.
The following instructions are addressed to the authorized installer, the
installation and maintenance must always be carried out by qualified personnel
and/or authorized technicians.
Warning: Unplug the gas hob from the electrical outlet before carrying
out any maintenance work.
Room ventilation
This gas hob must be installed and used in rooms with permanent ventilation
and adequate to current regulations. The following requirements must be
considered:
a)
The room must be prepared with a ventilation system that facilitates the
exit of smoke and combustion gases to the outside. In specific cases it is
possible to resort to electric hoods or extractors to force ventilation.
Through an extractor Directly outside
.