12
Gas supply connection via rigid or flexible tube
Very important!
•
Before carrying out any work related to the gas installation, check that
the gas supply is cut off or closed.
•
The connection of the gas outlet for both rigid and flexible tubes must be
carried out by an authorized installer.
•
The gas hob comes by default with injectors for butane gas (G30),
in the case of using natural gas (G20) the injectors (supplied)
suitable for natural gas must be changed.
•
Make sure that the gas supply pressure is within the values specified in
table 3.
•
Connect the appliance to the gas tap from the shortest path, for safety
reasons the tube used must be a maximum of 125 cm and a minimum of
40 cm in length.
•
When checking for gas leaks, NEVER use an open flame (match, lighter,
etc.). Apply soapy water on the joints and unions, if bubbles come out it
is an indication that there is a gas leak.
•
If the gas hob is to be installed in a cupboard or drawer that can be
opened, a protection panel must be mounted between the base of the
gas hob and the cabinet or drawer, respecting a space of at least 15 mm
below the gas plate.
Gas supply connection via flexible tube
Use the adapter for the flexible tube with the
corresponding gasket.
The flexible tube must be approved and its length
cannot exceed 125 cm in length. Once the
installation is complete, check that there are no
gas leaks and that the flexible tube is not crushed
or deformed.
Warning¡
The flexible gas tube, as well as the cable for the electrical connection, must
not pass near areas that acquire high temperatures, such as the base of the
gas hob or an oven.
The angles or elbows of the
flexible gas tube must be wide
to avoid being crushed or
deformed.