Innovator Plus System Operations Manual
Page | 27
plastic stylus device with a minimum tip radius of 1 mm (0.040 in.) to prevent damage to the
screen.
1. Click
Display
on the menu list.
2. Click Calibrate Touchscreen.
3. Briefly press and hold the stylus on the center of the target and repeat as the target moves
around the screen.
4. Click the
OK
message within 30 seconds to accept the changes.
Replace the Battery
The HMI terminal contains a lithium battery to provide backup for the real-time clock. It is not
used for application backup or retention.
WARNING
Shut off power before beginning any service.
Work in a static-free area with a grounded electrostatic discharge (ESD)
wristband. Avoid touching exposed electronic components to prevent
damage from ESD.
The battery is located on the back of
the terminal. No special tools are
required.
5. Remove the terminal from the
unit.
6. Remove the round battery cover
on the back of the terminal.
7. Remove the used battery and
replace with 2711P-RY2032 or a
manufacturer’s equivalent
(Matsushita or Duracell
DL2032).
8. Dispose of used batteries in
accordance with local
regulations.
Troubleshooting
HMI Panel
If the terminal does not start up correctly, check for:
Adequate power
State message or status codes