Innovator Plus System Operations Manual
Page | 24
Recipe Load Screen Fields
Field
Description
Mold Number
The injection tool tracking identifier (RFID only)
Part Number
Part tracking identifier (barcode only)
Serial Number
Serial tracking identifier (barcode only)
Operator ID
Operator tracking identifier (barcode only)
Injection Size
Material quantity to dispense
Catalyst Start
Hardener start percentage (PSD only)
Catalyst Stop
Hardener stop percentage (PSD only)
Pause At
Point at which the injection cycle pauses. There are 3 pauses available
during the injection.
Pump Pressure
Pressure to supply the injection pump (EPPC only)
MPG Pressure Low
Low setting of the EMPG to restart injection process (EMPG only)
MPG Pressure High
High setting of the EMPG to stop the injection process (EMPG only)
First Time Start Up
If the system has been used previously, skip to Daily Start Up.
5. Turn the pump regulator to zero (0).
6. Adjust the catalyst percentage using the slave arm knob.
7. With all the material containers properly filled, press the recirculation button on the control
panel.
8. Slowly increase the pump
regulator until the pump begins
to stroke slowly and evenly.
9. Allow the pump to recirculate
until the flow of resin and
catalyst back to their respective
containers is free of air bubbles.
10. Press the
Stop
button to take the
unit out of recirculation mode.
11. Place a suitable waste container
under the injection head and
press the
Inject
button.
12. After 4 or 5 strokes of the pump,
press the
Stop
button.
13. Check to make sure the material
properly cures.
14. Properly dispose of the dispensed material.
15. Flush the injection head as necessary.
WARNING
Do not load a recipe while injecting.