Innovator Plus System Operations Manual
Page | 26
20. If any fields change to red and/or an alarm sounds, address the error and press
Alarm Reset
.
Note
The Injection Monitor screen displays real-time data from the injection
process. Red fields indicate an error separate from the master alarm
indicators. Pressing the Alarm Reset will deactivate the alarm for a pre-
configured amount of time. If the alarm was not addressed or remained active
after the reset window passed, it will sound again.
21. When injection is complete, press
Stop
, then the
Reset
button on the counter.
22. Connect the next part or flush the system.
23. Flush the injection head as necessary.
Daily Shut Down
24. Close the TAS or pinch the injection hose to close the mold.
25. Press the
Reset
button on the counter to reset the counter.
26. Flush the injection head and hose or TAS.
27. Disconnect the injection hose or TAS from the injection head.
28. Turn off the main air slide valve on the back of the unit.
Maintaining the HMI
Calibrate Touch Screen
Over time objects and images on the display screen may not display as well as they did
originally. This is a normal maintenance issue with a touch screen and is easily fixed. Use a