IMPORTANT:

1.  Water Supply Service Stop Valve, Water Connections and Electrical Connections to be supplied by 

others in accordance with local codes.

4.  Completely flush supply lines of all foreign debris before connecting to fixture. Water cooler 

designed to not cause problems with taste, odor, color, or sediment. Optional water filter (WF1), is 
available should any of these problems arise from the water supply.

5.  Do NOT solder tubes inserted into the chiller or the fountain strainer as damage to the o-rings on 

the push-in fittings may result.

7.  Power supply must be identical in voltage, cycle and phase to that specified on the chiller data 

plate.

9.  WARNING: Warranty is voided if installation is not made following current Acorn Engineering 

installation instructions and if components are assembled to the fixture that are not approved by 
Acorn Engineering.

10.  Fixture operates within water pressure range of 20 to 105 psig. Acorn Engineering will not warranty 

chiller damaged when connected to supply lines with flow pressure lower that 20 psig or higher 
than 105 psig. A pressure regulator must be furnished by others on supply line if inlet pressure is 
greater than 105 psig.

11.  Due to cold waste water, Acorn Engineering recommends that waste piping supplied by installer be 

insulated appropriately to prevent excessive condensation.

6.  All burrs must be removed from outside of cut tubes before inserting into strainer or other 

components.

8.  This unit must be grounded per the requirements of applicable electrical codes.

12.  Per UPC 609.10-

All building water supply systems in which quick acting valves are installed shall 

be provided with devices to absorb the hammer caused by high pressure resulting from the quick 
closing of the valve. These pressure-absorbing devices shall be approved mechanical devices. 
Water pressure-absorbing devices shall be installed as close as possible to the quick closing valve.

2.  Provide 4” minimum clear space in front of bottom trim panel and above in-wall chiller to allow for 

proper ventilation.

3.  Waste is 1-1/4” Outer Diameter. Chiller water inlet is 3/8” Outer Diameter copper tube. Chiller water 

outlet is 3/8” Outer Diameter copper tube. Drinking Fountain water inlet is 3/8” Outer Diameter 
copper tube. Water line by others from in-wall chiller to drinking fountain must have adequate 
insulation.

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

 

A152.8FG

Page 4 of 9

Revised: 

07/18/18

7020-006-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

Содержание A152.8FG Series

Страница 1: ... Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement thereof This warranty is in lieu of all other warranties expressed or implied Product maintenance instructions are issued with each unit and disregard or non complian...

Страница 2: ...compliant parallel approach installation decrease height of installation by 3 inches Provide clear floor space as required Adjust vertical dimensions as required to comply with federal state and local codes I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A152 8FG Pa...

Страница 3: ...T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A152 8FG Page 3 of 9 Revised 07 18 18 7020 006 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of FINISHED FLOOR GENERAL NOTES 1 ALL DIMENSIONS ARE IN INCHES MM 2 DIMENSIONS SHOWN ARE FOR RECOMMENDED ADULT HEIGHT ADJUST VERTICAL DIMENSIONS AS NEC...

Страница 4: ...lied by installer be insulated appropriately to prevent excessive condensation 6 All burrs must be removed from outside of cut tubes before inserting into strainer or other components 8 This unit must be grounded per the requirements of applicable electrical codes 12 Per UPC 609 10 All building water supply systems in which quick acting valves are installed shall be provided with devices to absorb...

Страница 5: ...6 Slide fixture over studs and secure with nuts and washers 2 5 Remove the drinking fountain bottom access panels 1 Set the access panels aside in a safe place where they will not be damaged and place the screws in a secure location where they will not be lost I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E ...

Страница 6: ... begins to function TROUBLE SHOOTING IMPORTANT BEFORE MAKING ANY OF THE REPAIRS LISTED MAKE SURE THE WATER SUPPLY VALVE IS SHUT OFF a Cartridge The water flow can be adjusted using a slotted narrow blade screwdriver and turning clockwise to increase flow and counterclockwise to decrease flow b Cold Water Thermostat The water temperature can be adjusted using a slotted screwdriver and turning clock...

Страница 7: ... be cleaned using a clean soft cloth and mild soap with water or a mild glass cleaner c An incorrect refrigerant charge restriction or defective compressor not pumping will also cause the compressor to run without producing cold water All these signs indicate a problem within the refrigeration system and the water chiller must be checked by an authorized service company 5 Noisy Operation 4 Compres...

Страница 8: ...n fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep INSERTING THE TUBE COLLET COLLET O RING O RING TUBE STOP COLLET COLLET COLLET I N S TA L L AT I O N M A I N T...

Страница 9: ...ter P Trap 9 7000 068 001 Retaining Ring Button Assembly 4 7000 021 001 Y Strainer 10 7000 069 001 Valve Cartridge With Foam Washer 5 7000 005 199 Drain Adapter 11 7000 065 001 Recessed Pushbutton Valve Assembly 6 7000 006 000 Flat Drain Adapter Gasket 12 7003 093 001 Flow Restrictor Low Flow Bubbler Only 7 0152 010 000 Center Reject Allen Flat Head Screw 6 5 4 3 2 1 6 9 10 11 8B 8A 12 NOTE Flow R...

Отзывы: