3. Compressor Runs – Water Is Warm

2.  Excess dirt or poor ventilation will cause the compressor overload protector to turn the compressor 

off and it will cycle on and off with no cold water coming out of bubbler. Periodically clean with 
vacuum cleaner, air hose or brush the condenser fins and cabinet ventilation louvers. In 
environments where dirt and dust is more prevalent, clean more frequently.

 

a.  Ensure water supply service stop valve is fully open.

CLEANING & MAINTENANCE GUIDE:

3.  Periodically remove fountain top and clean out in-line strainer.

 

b.  Verify minimum 20 psig supply line flow pressure.

6. Restricted Or No Water Flow

 

f.  The water chiller may also develop a freezing condition in which the water will become frozen 

inside the evaporator coil. This indicates a refrigeration problem or thermostat failure in which 
case the water chiller needs to be checked by a qualified technician.

1.  Motors have lifetime lubrication and do not require scheduled maintenance.

4.  Do NOT use harsh chemicals, abrasive or petroleum based cleaners. Use of these will void the 

Acorn 

Engineering warranty.

 

a.  The most common cause for a water chiller to run without producing cold water is a loss of 

refrigerant. The water chiller must be taken to a certified refrigerant technician for repairs.

 

b.  Check the incoming voltage to make sure it is within 10% of the serial nameplate rating.

 

b.  Replace valve cartridge.

 

a.  A dirty condenser or a blocked fan will cause a high head pressure and frequent cycling of the 

overload protector.

 

a.  Check to make sure the fan blade is rotating freely.

5.  Exterior panels can be cleaned using mild household detergents or warm, soapy water. Extra care 

must be used cleaning chrome plated items and mirror finished stainless steel. They can scratch 
easily and should only be cleaned using a clean, soft cloth and mild soap with water or a mild glass 
cleaner.

 

c.  An incorrect refrigerant charge, restriction or defective compressor (not pumping) will also cause 

the compressor to run without producing cold water. All these signs indicate a problem within 
the refrigeration system and the water chiller must be checked by an authorized service 
company.

5. Noisy Operation

4. Compressor Cycling On Overload Protector

 

d.  Change the overload or relay if defective.

 

b.  Check the compressor mounting to make sure the pins and clips are not rattling. If the 

compressor appears to be noisy internally, it must be replaced.

 

b.  Make sure the condenser fan motor is operative. The fan blade must turn freely to help remove 

the heat of compression.

 

c.  Check for twists or kinks in outlet tubing.

 

d.  Check the water inlet strainer. Sediment from the main supply can get trapped in the screen 

along with installation materials such as pipe dope and flux. The screen should be cleaned and 
checked on a regular basis and replace if needed.

 

e.  The cartridge valve located in the water control assembly or bubbler can also become clogged 

with foreign material. The cartridge valve can only be replaced and not repaired.

 

c.  A restriction or moisture in the system will also cause intermittent cycling. A certified refrigeration 

mechanic should be contacted in this situation.

7. Water Drips Or Will Not Shut Off
 

a.  Open fixture. Loosen nuts holding valve bracket assembly to bottom of fixture but do not 

remove. Move complete valve bracket assembly further back from the front push pad and 
tighten to lock in place.

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

 

A152.8FG

Page 7 of 9

Revised: 

07/18/18

7020-006-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

Содержание A152.8FG Series

Страница 1: ... Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the materials or any delay in the repair or replacement thereof This warranty is in lieu of all other warranties expressed or implied Product maintenance instructions are issued with each unit and disregard or non complian...

Страница 2: ...compliant parallel approach installation decrease height of installation by 3 inches Provide clear floor space as required Adjust vertical dimensions as required to comply with federal state and local codes I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A152 8FG Pa...

Страница 3: ...T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS A152 8FG Page 3 of 9 Revised 07 18 18 7020 006 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of FINISHED FLOOR GENERAL NOTES 1 ALL DIMENSIONS ARE IN INCHES MM 2 DIMENSIONS SHOWN ARE FOR RECOMMENDED ADULT HEIGHT ADJUST VERTICAL DIMENSIONS AS NEC...

Страница 4: ...lied by installer be insulated appropriately to prevent excessive condensation 6 All burrs must be removed from outside of cut tubes before inserting into strainer or other components 8 This unit must be grounded per the requirements of applicable electrical codes 12 Per UPC 609 10 All building water supply systems in which quick acting valves are installed shall be provided with devices to absorb...

Страница 5: ...6 Slide fixture over studs and secure with nuts and washers 2 5 Remove the drinking fountain bottom access panels 1 Set the access panels aside in a safe place where they will not be damaged and place the screws in a secure location where they will not be lost I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E ...

Страница 6: ... begins to function TROUBLE SHOOTING IMPORTANT BEFORE MAKING ANY OF THE REPAIRS LISTED MAKE SURE THE WATER SUPPLY VALVE IS SHUT OFF a Cartridge The water flow can be adjusted using a slotted narrow blade screwdriver and turning clockwise to increase flow and counterclockwise to decrease flow b Cold Water Thermostat The water temperature can be adjusted using a slotted screwdriver and turning clock...

Страница 7: ... be cleaned using a clean soft cloth and mild soap with water or a mild glass cleaner c An incorrect refrigerant charge restriction or defective compressor not pumping will also cause the compressor to run without producing cold water All these signs indicate a problem within the refrigeration system and the water chiller must be checked by an authorized service company 5 Noisy Operation 4 Compres...

Страница 8: ...n fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep INSERTING THE TUBE COLLET COLLET O RING O RING TUBE STOP COLLET COLLET COLLET I N S TA L L AT I O N M A I N T...

Страница 9: ...ter P Trap 9 7000 068 001 Retaining Ring Button Assembly 4 7000 021 001 Y Strainer 10 7000 069 001 Valve Cartridge With Foam Washer 5 7000 005 199 Drain Adapter 11 7000 065 001 Recessed Pushbutton Valve Assembly 6 7000 006 000 Flat Drain Adapter Gasket 12 7003 093 001 Flow Restrictor Low Flow Bubbler Only 7 0152 010 000 Center Reject Allen Flat Head Screw 6 5 4 3 2 1 6 9 10 11 8B 8A 12 NOTE Flow R...

Отзывы: