6.  All burrs must be removed from outside of cut tubes before inserting into coupler or other 

components. 

Important: some options may slightly alter installation. To ensure proper installation review the manual 
thoroughly and verify rough-ins before beginning any work. File this manual with the owner or 
maintenance personnel upon completion of installation.

8.  This unit must be grounded per the requirements of applicable electrical codes. 

5.  Do NOT solder tubes inserted into the coupler as damage to the o-ring may result.

10.  Fixture operates within water pressure range of 20 to 105 PSIG. Murdock Manufacturing will not 

warranty fixtures damaged when connected to supply lines with flow pressure lower than 20 PSIG 
or higher than 105 PSIG. A pressure regulator must be furnished by others on supply line if inlet  
pressure is greater than 105 PSIG. 

IMPORTANT:

4.  Completely flush supply lines of all foreign debris before connecting to fixture. Water cooler is 

designed to not cause problems with taste, odor, color, or sediment. Optional water filter (WF1) is 
available should any of these problems arise from the water supply. 

7.  Power supply must be identical in voltage, cycle and phase to that specified on the cooler data 

plate. Wire Harness must be used to supply power to Chiller. Do NOT wire compressor directly to 
the power supply. 

PRIOR TO INSTALLATION

9.  WARNING: Warranty is voided if installation is not made following current Murdock Manufacturing 

installation instructions and if components are assembled to the fixture that is not approved by 
Murdock Manufacturing. 

1.  Water Supply Service Angle Stop Valve and 2” x 4” Electrical Plug-In Receptacle to be supplied by 

others in accordance with local codes. A metallic P-Trap must be used for the drain connection.

11.  Per UPC 609.10-

 All building water supply systems in which quick acting valves are installed shall 

be provided with devices to absorb the hammer caused by high pressure resulting from the quick 
closing of the valve. These pressure-absorbing devices shall be approved mechanical devices. 
Water pressure-absorbing devices will be installed as close as possible to the quick closing valve.

3.  Water supply is 3/8” Outer Diameter copper tube. Waste is 1-1/4” Outer Diameter.

2.  Provide 4” minimum clear space on fixture sides to allow for proper ventilation through cabinet 

louvers.

Fixture mounting requirements: Industry standard wall construction, adequate to support the fixture 
and installer provided wall anchors sufficient to secure the fixture.

Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth grounded per NEC 
(National Electrical Code).

Inspect fixture and all parts from damages and all parts are bolted on.

 

 

A151.8-VR

Page 4 of 11

Date: 

11/10/2020

7021-024-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

Содержание A151.8-VR Series

Страница 1: ...s not apply to materials which have been damaged by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the material...

Страница 2: ...h installation Adjust vertical dimension as required to comply with federal state and local codes For Child ADA compliant parallel approach decrease spout height to 30 maximum above finished floor Provide clear floor space as required A151 8 VR Page 2 of 11 Date 11 10 2020 7021 024 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 486...

Страница 3: ...20 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of FINISHED FLOOR 293 8 SUPPLY INLET 291 2 WASTE OUTLET 383 8 BLOCKOUT 19 BLOCKOUT 2 57 8 C L 1 1 1 1 4 P Trap Waste Outlet 1 3 8 OD Supply Inlet 2 General Notes 1 Dimension indicated with is for 33 Drinking Fountain discharge height If discharge heigh...

Страница 4: ... made following current Murdock Manufacturing installation instructions and if components are assembled to the fixture that is not approved by Murdock Manufacturing 1 Water Supply Service Angle Stop Valve and 2 x 4 Electrical Plug In Receptacle to be supplied by others in accordance with local codes A metallic P Trap must be used for the drain connection 11 Per UPC 609 10 All building water supply...

Страница 5: ...ame 5 Remove the drinking fountain top 1 by taking out the drain screw 2 and lifting at the front while pulling forward Disconnect bubbler tube 3 Set top 1 aside in a safe place where it will not be damaged Place the screw 2 in a secure location where it will not be lost 6 Slide fixture over studs and secure with nuts and washers 4 A151 8 VR Page 5 of 11 Date 11 10 2020 7021 024 001 MURDOCK MFG 15...

Страница 6: ...nd check all connections for leaks 4 Recheck all water connections with water flowing through system TROUBLE SHOOTING a Cartridge The water flow can be adjusted using a slotted narrow blade screwdriver and turning clockwise to increase flow and counterclockwise to decrease flow 6 Assemble louvered bottom trim panel with screws provided to brackets on either side of wall mounting frame 7 Assemble P...

Страница 7: ... loss of refrigerant The water chiller must be taken to a certified refrigerant technician for repairs b Make sure the condenser fan motor is operative The fan blade must turn freely to help remove the heat of compression 4 Compressor Cycling On Overload Protector b Check the incoming voltage to make sure it is within 10 of the serial nameplate rating 5 Noisy Operation a Check to make sure the fan...

Страница 8: ...py water Extra care must be used cleaning chrome plated items and mirror finished stainless steel They can scratch easily and should only be cleaned using a clean soft cloth and mild soap with water or a mild glass cleaner c There is debris or scale in the center or two hole in convolution of the water diaphragm Remove and clean a Repair bad connection from sensor to solenoid b There is debris or ...

Страница 9: ...Cartridge Retaining Nut Remove and replace Cartridge When replacing Cartridge be sure to align the inlet and outlet Ports on the Cartridge with the Ports in the Valve Body NOTE STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW 1 Strainer Plug must be removed before Cartridge replacement and Strainer maintenance no need to turn the water off at the Angle Stop Some residual water will drainduring P...

Страница 10: ... tubing to remove from the push in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square INSERTING THE TUBE 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep COLLET COLLET O RING O RING TUBE STOP COLLET COLLET COLLE...

Страница 11: ...bler ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER DESCRIPTION 1 7000 005 199 Drain Adapter 9 7003 193 000 Spring Pushbutton Return 2 0116 016 000 10 32 x 3 8 Phillips Truss Head Screw 10 7003 196 199 Pushbutton Chrome 3 7000 006 000 Flat Drain Adapter Gasket 11 7003 197 199 Escutcheon Chrome 4 7000 015 000 1 1 4 OD P Trap 12 0161 062 000 6 32 x 1 2 Phillips Flat Head Screw 5 0152 010 000 10 32 x ...

Отзывы: