6. All burrs must be removed from outside of cut tubes before inserting into coupler or other
components.
Important: some options may slightly alter installation. To ensure proper installation review the manual
thoroughly and verify rough-ins before beginning any work. File this manual with the owner or
maintenance personnel upon completion of installation.
8. This unit must be grounded per the requirements of applicable electrical codes.
5. Do NOT solder tubes inserted into the coupler as damage to the o-ring may result.
10. Fixture operates within water pressure range of 20 to 105 PSIG. Murdock Manufacturing will not
warranty fixtures damaged when connected to supply lines with flow pressure lower than 20 PSIG
or higher than 105 PSIG. A pressure regulator must be furnished by others on supply line if inlet
pressure is greater than 105 PSIG.
IMPORTANT:
4. Completely flush supply lines of all foreign debris before connecting to fixture. Water cooler is
designed to not cause problems with taste, odor, color, or sediment. Optional water filter (WF1) is
available should any of these problems arise from the water supply.
7. Power supply must be identical in voltage, cycle and phase to that specified on the cooler data
plate. Wire Harness must be used to supply power to Chiller. Do NOT wire compressor directly to
the power supply.
PRIOR TO INSTALLATION
9. WARNING: Warranty is voided if installation is not made following current Murdock Manufacturing
installation instructions and if components are assembled to the fixture that is not approved by
Murdock Manufacturing.
1. Water Supply Service Angle Stop Valve and 2” x 4” Electrical Plug-In Receptacle to be supplied by
others in accordance with local codes. A metallic P-Trap must be used for the drain connection.
11. Per UPC 609.10-
All building water supply systems in which quick acting valves are installed shall
be provided with devices to absorb the hammer caused by high pressure resulting from the quick
closing of the valve. These pressure-absorbing devices shall be approved mechanical devices.
Water pressure-absorbing devices will be installed as close as possible to the quick closing valve.
3. Water supply is 3/8” Outer Diameter copper tube. Waste is 1-1/4” Outer Diameter.
2. Provide 4” minimum clear space on fixture sides to allow for proper ventilation through cabinet
louvers.
—
Fixture mounting requirements: Industry standard wall construction, adequate to support the fixture
and installer provided wall anchors sufficient to secure the fixture.
—
Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth grounded per NEC
(National Electrical Code).
—
Inspect fixture and all parts from damages and all parts are bolted on.
A151.8-VR