background image

A151.8-VR Series

Barrier Free, Vandal Resistant Wall Mounted Electric Drinking Fountain 

A151408F-VR / A151408S-VR 

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER: 

1.800.591.9360

Technical Assistance Fax: 1.626.855.4894

Murdock warrants that every cooler, bottle filling station, packaged water chiller, fountain and accessory to be free 
from defects in material and workmanship under normal use for one (1) year from date of install or eighteen (18) 
months after the date of shipment from the factory, whichever comes first. 

LIMITED EXPORT WARRANTY - 

One year on parts only. 

NOTES TO INSTALLER:

1. Please leave this documentation with the owner of the fixture when finished. 
2. Please read this entire booklet before beginning the installation. 
3. Check your installation for compliance with plumbing, electrical and other applicable codes.

Murdock warrants the compressor and hermetically sealed refrigeration system, including cooling coil assembly 
when part of the hermetically sealed refrigeration system, to be free from defects in material and workmanship 
under normal use for an additional four (4) years from the end of the one (1) year period described above.

LIMITED WARRANTY - UNITED STATES & CANADA

This warranty does not cover installation or labor charges and does not apply to materials, which have been 
damaged by other causes such as mishandling or improper care or abnormal use. The repair or replacement of the 
defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this 
warranty. Murdock shall not be liable under any circumstances for incidental, consequential or direct charges 
caused by defects in the materials, or any delay in the repair or replacement thereof.  This warranty is in lieu of all 
other warranties expressed or implied. Product maintenance instructions are issued with each unit and disregard 
or non-compliance with these instructions will constitute an abnormal use condition and void the warranty. 
Stainless steel must be protected on job site during construction and must be properly maintained after the water 
has been introduced into the water cooler or drinking fountain, or Murdock’s limited warranty is void.

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

COMPLIES 

WITH

7021-024-001    

 Date: 11/10/2020

Federal
Public Law
111-380 
(No Lead)

Murdock assumes no responsibility for use of void or 
suspended data. © Copyright Murdock, City of 
Industry, CA Member of  Morris Group International. 
Please visit 

www.murdockmfg.com 

for most 

current specifications.

Member of

15125 Proctor Ave, City of Industry,

CA, 91746 U.S.A.

Phone 800-591-9360

626-336-4561

Fax 626-855-4894

www.murdockmfg.com

 

Содержание A151.8-VR Series

Страница 1: ...s not apply to materials which have been damaged by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direct charges caused by defects in the material...

Страница 2: ...h installation Adjust vertical dimension as required to comply with federal state and local codes For Child ADA compliant parallel approach decrease spout height to 30 maximum above finished floor Provide clear floor space as required A151 8 VR Page 2 of 11 Date 11 10 2020 7021 024 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 486...

Страница 3: ...20 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of FINISHED FLOOR 293 8 SUPPLY INLET 291 2 WASTE OUTLET 383 8 BLOCKOUT 19 BLOCKOUT 2 57 8 C L 1 1 1 1 4 P Trap Waste Outlet 1 3 8 OD Supply Inlet 2 General Notes 1 Dimension indicated with is for 33 Drinking Fountain discharge height If discharge heigh...

Страница 4: ... made following current Murdock Manufacturing installation instructions and if components are assembled to the fixture that is not approved by Murdock Manufacturing 1 Water Supply Service Angle Stop Valve and 2 x 4 Electrical Plug In Receptacle to be supplied by others in accordance with local codes A metallic P Trap must be used for the drain connection 11 Per UPC 609 10 All building water supply...

Страница 5: ...ame 5 Remove the drinking fountain top 1 by taking out the drain screw 2 and lifting at the front while pulling forward Disconnect bubbler tube 3 Set top 1 aside in a safe place where it will not be damaged Place the screw 2 in a secure location where it will not be lost 6 Slide fixture over studs and secure with nuts and washers 4 A151 8 VR Page 5 of 11 Date 11 10 2020 7021 024 001 MURDOCK MFG 15...

Страница 6: ...nd check all connections for leaks 4 Recheck all water connections with water flowing through system TROUBLE SHOOTING a Cartridge The water flow can be adjusted using a slotted narrow blade screwdriver and turning clockwise to increase flow and counterclockwise to decrease flow 6 Assemble louvered bottom trim panel with screws provided to brackets on either side of wall mounting frame 7 Assemble P...

Страница 7: ... loss of refrigerant The water chiller must be taken to a certified refrigerant technician for repairs b Make sure the condenser fan motor is operative The fan blade must turn freely to help remove the heat of compression 4 Compressor Cycling On Overload Protector b Check the incoming voltage to make sure it is within 10 of the serial nameplate rating 5 Noisy Operation a Check to make sure the fan...

Страница 8: ...py water Extra care must be used cleaning chrome plated items and mirror finished stainless steel They can scratch easily and should only be cleaned using a clean soft cloth and mild soap with water or a mild glass cleaner c There is debris or scale in the center or two hole in convolution of the water diaphragm Remove and clean a Repair bad connection from sensor to solenoid b There is debris or ...

Страница 9: ...Cartridge Retaining Nut Remove and replace Cartridge When replacing Cartridge be sure to align the inlet and outlet Ports on the Cartridge with the Ports in the Valve Body NOTE STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW 1 Strainer Plug must be removed before Cartridge replacement and Strainer maintenance no need to turn the water off at the Angle Stop Some residual water will drainduring P...

Страница 10: ... tubing to remove from the push in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square INSERTING THE TUBE 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep COLLET COLLET O RING O RING TUBE STOP COLLET COLLET COLLE...

Страница 11: ...bler ITEM PART NUMBER DESCRIPTION ITEM PART NUMBER DESCRIPTION 1 7000 005 199 Drain Adapter 9 7003 193 000 Spring Pushbutton Return 2 0116 016 000 10 32 x 3 8 Phillips Truss Head Screw 10 7003 196 199 Pushbutton Chrome 3 7000 006 000 Flat Drain Adapter Gasket 11 7003 197 199 Escutcheon Chrome 4 7000 015 000 1 1 4 OD P Trap 12 0161 062 000 6 32 x 1 2 Phillips Flat Head Screw 5 0152 010 000 10 32 x ...