  Do not direct the hot air jet of the hand extruder 

towards living beings or temperature-sensitive 
items.  

 

Safety distance: 2 m radius 
 

 

B

ILD 

D02-0002 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

  Use suitable personal protection equipment for 

overhead work (e.g. hard hat, safety goggles, 
gloves, protective clothes …) to guard against  
falling items. 

  During work breaks and after completion of the 

welding job, place the hand extruder on the rests 
supplied for this purpose. 

 

CAUTION The hot air hood must be remounted.  

 

 Make sure that the hand extruder is firmly 

positioned! 

 

Deposit the hand extruder in a dry location.  
 
After completion of the welding job, cool the hand 
extruder to safe-to-touch temperature, using the 
air supply system. 
 

 

 Do not operate, dismantle or carry out any 

modifications on the hand extruder, if  
-   the connecting cable or the mains connector
     is defective,  
-   safety devices are damaged,  
-   foreign matter or liquid has penetrated into the 
    hand extruder, 
-   the unit does not work properly or there are  
    unusual changes in its operating behaviour. 
 

 

 Never allow the hand extruder to come into 

contact with water: Hazard to persons and 
equipment, short-circuit risk. 

 

2.6  Safety instructions for maintenance, inspec-

tion and mounting 

The Operator is responsible for ensuring that main-
tenance, inspection and mounting activities are per-
formed by authorized and qualified personnel who 
are thoroughly familiar with the operating instruc-
tions. 
 

  As a rule, the hand extruder must be shut off and 

the connector unplugged before proceeding to 
any work on the unit. The shutoff procedure for 
the hand extruder described in the operating in-
structions must be strictly observed. 

  Electrical hazards must be ruled out (for details, 

see VDE guidelines and the standards of your lo-
cal electric utility, for instance). 
 

 

 VDE 0701 (IEC 335) prescribes the meas-

urement of the protective conductor resistance, 
insulation resistance and leakage current after 
each repair or modification to electrical equip-
ment. Furthermore, a visual inspection of the unit 
and its connecting cable as well as voltage and 
current measurements and a function test must 
be carried out. 

  Ensure the safe and environmentally compatible  

disposal of media, auxiliary materials and re-
placed parts! 

  Remount and reactivate all safety and protective 

devices immediately on completion of the main-
tenance, inspection or repair work. 

 
2.7  Unauthorized modifications and spare parts 
Modifications or changes to the unit are only allowed 
after consultation with the Manufacturer. In the inter-
est of safety, only original spare parts and accesso-
ries authorized by the Manufacturer should be used. 
The use of components other than the original spare 
parts may invalidate the Manufacturer’s liability for 
any resulting damage. 
 

 

D02-0002

3

6

0

°

2 m

(6 f

t)

 

Содержание MAK-40

Страница 1: ...o ______________ MEK 65 MAK 65 Article No ______________ These operating instructions contain important information to be observed for hand extruder operation and maintenance It is therefore imperativ...

Страница 2: ...UNTING 7 2 7 UNAUTHORIZED MODIFICATIONS AND SPARE PARTS 7 3 TRANSPORT AND STORAGE 8 3 1 TRANSPORT 8 3 2 STORAGE 8 3 3 RETURN TO MUNSCH 8 4 PRODUCT DESCRIPTION 8 4 1 APPLICATION RANGE 8 4 2 GENERAL 8 5...

Страница 3: ...EU Machinery Directive 98 37 EC EU EMC Directive 89 336 EC EN 61029 1 VDE 0740 Part 500 DIN EN 55014 1 VDE 0701 Part 1 DIN EN 55014 2 VDE 0702 Part 1 DIN EN ISO 12100 1 EU Low Voltage Directive 73 23...

Страница 4: ...r failure to observe the safety instructions may lead to the forfeiture of any damages Non observance of the safety instructions may in particular involve the following risks failure of important hand...

Страница 5: ...not less than 230 V 1 must be available at the connector of the hand extruder When using an extension cable make sure to observe the minimum conductor cross section Use extension cables with protecti...

Страница 6: ...ir supply risk of hand extruder dam age When using an external air source make sure that the air supply line is adequately dimen sioned CAUTION The supply air must be clean dry and free from oil and w...

Страница 7: ...tion and mounting activities are per formed by authorized and qualified personnel who are thoroughly familiar with the operating instruc tions As a rule the hand extruder must be shut off and the conn...

Страница 8: ...er in a dry and frost free place Protect the hand extruder from unauthorized ac cess Special preservation is not required 3 3 Return to Munsch Should it become necessary to return the hand ex truder t...

Страница 9: ...ted The temperature controlled start interlock prevents the drive from starting if there is still unmolten mate rial in the extruder thus precluding damage to the unit The output rate is variable so t...

Страница 10: ...ossible For larger weld seam widths a wider preheat nozzle is available as an accessory 5 3 Starting the hand extruder Observe section Safety CAUTION Never operate the hand extruder with out air suppl...

Страница 11: ...t be clean and dry 5 4 1 Introducing the welding rod CAUTION The hand extruder is provided with a bore for introducing the welding rod 5 4 2 Replacement and aging of welding rod If the welding rod is...

Страница 12: ...once to switch off the heat ing circuits Pull mains connector Maintain the air supply of the hand ex truder until the unit has completely cooled down Never use water or another coolant to accelerate t...

Страница 13: ...MEK 40 65 MAK 40 65 Issue 08 2008 Rev 01 Page 13 20...

Страница 14: ...e and proper working practices must be observed Any working practices posing a safety risk are pro hibited Activities other than those described in this section may only be performed at the Manufactur...

Страница 15: ...MEK 40 65 MAK 40 65 Issue 08 2008 Rev 01 Page 15 20...

Страница 16: ...temperature 2 3 4 8 10 18 22 14 Melt temperature below setpoint temperature 2 3 9 11 14 Extruder does not heat up 2 3 12 22 Temperature above preset range 2 3 18 19 Controller fault signal E 2 Contro...

Страница 17: ...ltage Rated voltage permissible voltage Check mains voltage 1 15 Extension cable heats up Unroll cable reel Check cable cross section see also section Sa fety 16 Extruder nozzle plugged with foreign m...

Страница 18: ...ilm sheeting welds Weight 40 7 9 kg 65 8 9 kg 40 8 kg 65 9 4 kg Drive 230 V AC with speed control external Powerbox 230 V AC with speed control external Powerbox Extruder heating system 40 650 W 65 80...

Страница 19: ...be free from defects in materials and workmanship from the date of its first acquisition Should deficiencies resulting from defects in materials or work manship be identified during the warranty peri...

Страница 20: ...t the Purchaser may demand annulment cancella tion of the contract or a price reduction reduc tion of compensation in lieu of remedial work In such a case the Purchaser shall not be entitled to any re...

Отзывы: