3
Air Conditioner DC Duct Type
EN
4. INSTALLATION PLACE
The Indoor Unit
The Outdoor Unit
CAUTIONS
T
a
T
T
,
T
T
c
T
T
n
T
,
T
T
Y
t
T
I
l
Location in the following places may cause
malfunction of the machine. (If unavoidable, please
consult your local dealer.)
a. There exists petrolatum.
b. There is salty air surrounding(near the coast).
c. There is caustic gas(the sulfide, for example)
existing in the air (near a hot spring).
d. The Volt vibrates violently(in the factories).
e. In buses or cabinets.
f. In kitchen where it is full of oil gas.
g. There is strong electromagnetic wave existing.
h. There are inflammable materials or gas.
i. There is acid or alkaline liquid evaporating.
j. Other special conditions.
• here is enough roomfor installation and
mainten nce.
• he ceiling is horizontal, and its structure can
endure the weight of the indoor unit.
• he air outlet and the air inlet are not impeded
and the influence of external air is the least.
• he air flow can reach throughout the room.
• he connecting pipe and drainpipe could be
extra ted out easily.
• here is no direct radiation fromheaters
• here is enough room for installation and
mainte ance.
• he air outlet and the air inlet are not impeded
and can not be reached by strong wind.
• he place is dry and ventilative.
• he support is flat and horizontal and can stand
the weight of the outdoor unit. And no additional
noise or vibration.
• our neighborhood will not feel uncomfortable
wi h the noise or expelled air.
• here is no leakage of combustible gas.
• t is easy to install the connecting pipe or cab es.
NOTES BEFORE INSTALLATION
NOTE
1. Select the correct carry-in path.
2. Move this unit as originally packaged as
possible.
3. If the air conditioner is installed on a metal part
of the building, it must be electrically
insulated according to the relevant standards to
electrical appliances
Remark per EMC Directive 89/336/EEC
For to prevent flicker impressions during the start
of the compressor (technical process),
following installation conditions apply.
1. The power connection for the air conditioner has
to be done at the main power distribution.
The distribution has to be of a low impedance,
normally the required impedance reaches
a 32Afusing poinat t.
2. No other equipment has to be connected with
this power line.
3. For detailed installation acceptance, please
refer to your contract with the power supplier
if restrictions do apply for products like washing
machines, air conditioners or electrical
ovens.
4. For power details of the air conditioner, refer to
the rating plate of the product.
5. For any question contact your local dealer.
Содержание MUCR 12 HF
Страница 11: ...ES 10 Aire Acondicionado DC Conducto 12 ESQUEMAS ELECTRICOS 18000 24000 Btu h 36000 60000 Btu h...
Страница 12: ...ES 11 Aire Acondicionado DC Conducto 12 ESQUEMAS ELECTRICOS 18000 24000 Btu h 36000 60000 Btu h...
Страница 28: ...10 12 WIRING CHART Air Conditioner DC DuctType EN...
Страница 29: ...Air Conditioner DC DuctType EN 11 12 WIRING CHART...