WIRE CONTROLLER
To wire controller
DISPLAY BOARD
The reserved wire control function is indicated in broken
line table,users can purchase the wire controller when
necessary
Horsepower code
Code
Capacity(Horsepower)
0
1
2
3
4
2200W(0.8HP)
5600W(2.0HP)
4500W(1.5HP)
3600W(1.2HP)
2800W(1.0HP)
5
7100W(2.5HP)
Note: The horsepower
has been set before
leaving the factory ,
anyone can
̓
t
modify it except the
maintenance person.
0 1
2
3
4
56
78
9
A
B
C
D
E F
ENC1
POWER_S
For set horsepower
Toggle switch
ENC1
7.1 Terminal Board Diagram
Please refer to the indoor unit wiring diagram for the wiring.
NOTE
The air-conditioners can connect with Central Control Monitor
(CCM). Before operation, please wiring correctly and set
system address and network address of indoor units.
, and connect the shielded layed to .
MAIN BOARD
6
8000W(3.0HP)
7
9000W(3.2HP)
INDOOR UNIT POWER
220-240V
̚
̚
50/60Hz
XT1
Y/G
/ 1
RED
BLUE
POWER IN
RED
BLUE
POWER IN
INDOOR UNIT POWER
220-240V
̚
50/60Hz
To outdoor
COMM. BUS
To CCM
COMM. BUS
E Y X
CN21
CN20
Y/G
P
Q
(E)
X
Y
GRA
Y
YELLOW
BLUE
WHITE
To outdoor
COMM. BUS
To CCM
COMM. BUS
(BLACK)
XT2
CN1
L
N
BLACK
SW1
ON
SW1
ON
SW1
ON
S W 2
ON
S W 2
ON
SW6
O
N
ON
ON
SW5
ON
Installation manual
Wall mounted split
2.2/2.8 kW
3.6/4.5/5.6/7.1/8.0/9.0 kW
2.2/2.8 kW
3.6/4.5/5.6/7.1/8.0/9.0 kW
X Y E
E P Q
E Y X
P Q E
Please use 3-core shielded wire
7.2 Capacity set
Note: To make the addressing you can contact with
Mundoclima after sales service.
If the outdoor unit has Auto-address function is not necessary to
set manually the indoor unit address.
If the outdoor unit does not have the Auto-address function or if
you want to set the address manually, it should be done by
remote control (wireless or wired).
When connecting a centralized control, if all indoor units are
MVD D4+ or MVD DC series, the central control can be
connected directly to terminals XYE of the outdoor unit, you
must activate the Auto-address dip-switch (except 3 pipes system).
7.3 Indoor unit address set
The system together have 64units (0-63), everyone has only
system addresscode,If two addresses are the same in one
system, the abnormal operation will occur.
Please switch off the power before setting,otherwise the
unexpected error will occur.
CAUTION
8