When installing the unit in a small room, take measures 
against to keep refrigerant concentration from exceeding 
allowable safety limits in the event of refrigerant leakage.

 

Contact the place of purchase for more information. 
Excessive refrigerant in a closed ambient can lead to oxygen 
deficiency.

Use the attached accessories parts and specified parts 
for installation. 

otherwise, it will cause the set to fall, water  leakage, 
electrical shock fire.

Install at a strong and firm location which is able to 
withstand the set' s weight. 

If the strength is not enough or installation is not properly 
done, the set will drop to cause injury.

The appliance must be installed 2.5m above floor.

The appliance shall not be installed in the laundry.

Before obtaining access to terminals, all supply circuits 
must be disconnected.

The appliance must be positioned so that the plug is 
accessible.

The enclosure of the appliance shall be marked by word, 
or by symbols, with the direction of the fluid flow.

For electrical work, follow the local national wiring 
standard, regulation and this installation instructions. An 
independent circuit and single outlet must be used. 

If electrical circuit capacity is not enough or defect in 
electrical work, it will cause electrical shock fire.

Use the specified cable and connect tightly and clamp 
the cable so that no external force will be acted on the 
terminal.

 

If connection or fixing is not perfect, it will cause heat-up or 
fire at the connection.

Wiring routing must be properly arranged so that control 
board cover is fixed properly. 

If control board cover is not fixed perfectly, it will cause 
heat-up at connection point of terminal, fire or electrical 
shock.

If the supply cord is damaged, it must be replaced by the 
manufacture or its sevice agent or similarly qualifued 
person in order to avoid a hazard.

An all-pole disconnection switch having a contact 
separation of at least 3mm in all poles should be 
connected in fixed wiring.

This appliance can be children  aged from 8 yeas and 
above and persons with reduced physical,sensory or 
mental capabilities or lack of experience and knowledge 
if they have been given supervision or instruct.

The A-weighted sound pressure level is below 70dB.

When carrying out piping connection, take care not to let 
air substances go into refrigeration cycle. 

Otherwise, it will cause lower capacity, abnormal high 
pressure in the refrigeration cycle, explosion and injury.

Do not modify the length of the power supply cord or use 
of extension cord, and do not share the single outlet with 
other electrical appliances. 

Otherwise, it will cause fire or electrical shock.

Carry out the specified installation work after taking into 
account strong winds, typhoons or earthquakes.

Improper installation work may result in the equipment falling 
and causing accidents.

Be sure to be in conformity with the local, national and 
international laws and regulations.

Read "PRECAUTIONS" carefully before installation.

The following precautions include important safty items. 
Observe them and never forget.

Keep this manual with the owner's manual in a handy place 
for future reference.

Installation must be performed in accordance with the 
requirement of NEC and CEC by authorized personnel only.

1.    PRECAUTIONS

WARNING

WARNING

The safty precautions listed here are divided into two categories. In 
either case, important safty information is listed which must be read 
carefully.

After completing the installation, make sure that the unit operates 
properly during the start-up operation. Please instruct the customer 
on how to operate the unit and keep it maintained.Also, inform 
customers that they should store this installation manual along with 
the owner's manual for future reference.  

Be sure only trained and qualified service personnel to 
install, repair or service the equipment.

Improper installation, repair, and maintenance may result in 
electric shocks, short-circuit, leaks, fire or other damage to 
the equipment.

Install according to this installation instructions strictly. 

If installation is defective, it will cause water leakage, electric 
shocks, fire.

Failure to observe a warning may result in death.

CAUTION

Failure to observe a caution may result in injury or damage 
to the equipment.

CONTENTS

PAGE

PRECAUTIONS..........................................................................................1
INSTALLATION INFORMATION..................................................................2
ATTACHED  FITTINGS...............................................................................3
INSPECTING AND HANDLING THE UNIT...................................................4
INDOOR UNIT INSTALLATION...................................................................4
REFRIGERANT PIPE INSTALLATION..........................................................6
WIRING CHART.........................................................................................7
TEST OPERATION....................................................................................10

̚

̚

;

<

3

4

E Y X

P  Q E

;

<

3

4

SW1

ON

SW1

ON

SW1

ON

S W 2

ON

S W 2

ON

SW6

O

N

ON

ON

SW5

ON

Installation manual

Wall mounted split

1

Содержание CL23410

Страница 1: ...Installation manual English CL23410 to CL23416 Wall Mounted Split DC www mundoclima com www mundoclima com MVD...

Страница 2: ...given supervision or instruct The A weighted sound pressure level is below 70dB When carrying out piping connection take care not to let air substances go into refrigeration cycle Otherwise it will c...

Страница 3: ...n water leakage and property damage Install the indoor and outdoor units power supply wiring and connecting wires at least 1 meter away from televisions or radios in order to prevent image interferenc...

Страница 4: ...e controller to determine its location in a reception range Keep the remote controller at least 1m apart from the nearest TV set or stereo equipment it is necessary to prevent image disturbances or no...

Страница 5: ...l line Avoid installing it in a narrow sapce which has a high requirement to noise The ceiling is horizontal and its structure can endure the weight of the indoor unit The outlet and the inlet are not...

Страница 6: ...he wall Connect the indoor unit first then the outdoor unit and bend and arrange the pipe carefully Be careful not to let the drain hose slack Insulate both of the auxiliary piping 43 Indoor unit outl...

Страница 7: ...the compressor when compressor malfunction occurs 6 4 Connection of the Refrigerant Pipe Connection of the refrigerant pipe should be done by professionals Double span should be used when connecting...

Страница 8: ...e and a residual current device RCD with the rating of above 10mA shall be incorporated in the fixed wiring according to the nati onal rule CAUTION the wire holder of communication line two three posi...

Страница 9: ...CM COMM BUS E Y X CN21 CN20 Y G P Q E X Y GRAY YELLOW BLUE WHITE To outdoor COMM BUS To CCM COMM BUS BLACK XT2 CN1 L N BLACK Installation manual Wall mounted split 2 2 2 8 kW 3 6 4 5 5 6 7 1 8 0 9 0 k...

Страница 10: ...ent cold air SW6 Definition SW6 J1 Definition Without jumper J1 for auto restart function With jumper J1 for non auto restart function ON means 0 ON means 1 0 1 Definition Error code Content FE H0 E0...

Страница 11: ...on Whether the generated wind noise or condensed water by the air conditioner have influenced your neighborhood Whether any of the refrigerant is leaked 8 TEST OPERATION Protection function will delay...

Страница 12: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 80 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 www mundoclima com MVD...

Отзывы: