To install properly, please read this "installation manual" at 
first.

The air conditioner must be installed by qualified persons.

When installing the indoor unit or its tubing, please follow 
this manual as strictly as possible.

If the air conditioner is installed on a metal part of the 
building, it must be electrically insulated according to the 
relevant standards to electrical appliances.

When all the installation work is finished, please turn on the 
power only after a thorough check.

Regret for no further announcement if there is any change 
of this manual caused by product improvement.

2.    INSTALLATION INFORMATION

INSTALLATION ORDER

Select the location;

Install the indoor unit;

Install the outdoor unit;

Install the connecting pipe ;

Connect the drain pipe;

Wiring;

Test operation.

CAUTION

Ground the air conditioner.

Do not connect the ground wire to gas or water pipes, 
lightning rod or a telephone ground wire.Incomplete 
grounding may result in electric shocks.

Be sure to install an earth leakage breaker.

Failure to install an earth leakage breaker may result in 
electric shocks.

Connect the outdoor unit wires , then connect the indoor 
unit wires.

 

You are not allow to connect the air conditioner with the 
power source until w(including 
iring and piping the air conditioner is done.

While following the instructions in this installation 
manual, install drain piping in order to ensure proper 
drainage and insulate piping in order to prevent 
condensation.

Improper drain piping may result in water leakage and 
property damage.

Install the indoor and outdoor units, power supply wiring 
and connecting wires at least 1 meter away from 
televisions or radios in order to prevent image 
interference or noise.

Depending on the radio waves, a distance of 1 meter may not 
be sufficient enough to eliminate the noise.

The appliance is not intended for use by young children 
or infirm persons without supervision.

Young children should be supervised to ensure that they 
do not play with the appliance

.

Don't install the air conditioner in the following locations:

There is petrolatum existing.

There is salty air surrounding (near the coast).

There is caustic gas (the sulfide, for example) existing in 
the air (near a hot spring).

The Volt vibrates violently (in the factories).

In buses or cabinets.

In kitchen where it is full of oil gas.

There is strong electromagnetic wave existing.

There are inflammable materials or gas.

There is acid or alkaline liquid evaporating.

The appliance shall not be installed in the laundry.

Avoid installing it in a narrow sapce which has a high 
requirement to noise.

Other special conditions.

If the refrigerant leaks during installation, ventilate the 
area immediately.

Toxic gas may be produced if the refrigerant comes into the 
place contacting with fire.

After completing the installation work, check that the 
refrigerant does not leak.

Toxic gas may be produced if the refrigerant leaks into the 
room and comes into contact with a source of fire, such as a 
fan heater, stove or cooker.

The appliance shall be installed in accordance with 
national wiring regulations.

The power cord type designation is H05RN-R/H07RN-F or 
above.

̚

̚

;

<

3

4

E Y X

P  Q E

;

<

3

4

L

N

SW1

ON

SW1

ON

SW1

ON

S W 2

ON

S W 2

ON

SW6

O

N

ON

ON

SW5

ON

Installation manual

Wall mounted split

2

Содержание CL23410

Страница 1: ...Installation manual English CL23410 to CL23416 Wall Mounted Split DC www mundoclima com www mundoclima com MVD...

Страница 2: ...given supervision or instruct The A weighted sound pressure level is below 70dB When carrying out piping connection take care not to let air substances go into refrigeration cycle Otherwise it will c...

Страница 3: ...n water leakage and property damage Install the indoor and outdoor units power supply wiring and connecting wires at least 1 meter away from televisions or radios in order to prevent image interferenc...

Страница 4: ...e controller to determine its location in a reception range Keep the remote controller at least 1m apart from the nearest TV set or stereo equipment it is necessary to prevent image disturbances or no...

Страница 5: ...l line Avoid installing it in a narrow sapce which has a high requirement to noise The ceiling is horizontal and its structure can endure the weight of the indoor unit The outlet and the inlet are not...

Страница 6: ...he wall Connect the indoor unit first then the outdoor unit and bend and arrange the pipe carefully Be careful not to let the drain hose slack Insulate both of the auxiliary piping 43 Indoor unit outl...

Страница 7: ...the compressor when compressor malfunction occurs 6 4 Connection of the Refrigerant Pipe Connection of the refrigerant pipe should be done by professionals Double span should be used when connecting...

Страница 8: ...e and a residual current device RCD with the rating of above 10mA shall be incorporated in the fixed wiring according to the nati onal rule CAUTION the wire holder of communication line two three posi...

Страница 9: ...CM COMM BUS E Y X CN21 CN20 Y G P Q E X Y GRAY YELLOW BLUE WHITE To outdoor COMM BUS To CCM COMM BUS BLACK XT2 CN1 L N BLACK Installation manual Wall mounted split 2 2 2 8 kW 3 6 4 5 5 6 7 1 8 0 9 0 k...

Страница 10: ...ent cold air SW6 Definition SW6 J1 Definition Without jumper J1 for auto restart function With jumper J1 for non auto restart function ON means 0 ON means 1 0 1 Definition Error code Content FE H0 E0...

Страница 11: ...on Whether the generated wind noise or condensed water by the air conditioner have influenced your neighborhood Whether any of the refrigerant is leaked 8 TEST OPERATION Protection function will delay...

Страница 12: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 80 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 www mundoclima com MVD...

Отзывы: