WIRED CONTROLLER
To wired controller
DISPLAY BOARD
The reserved wired control function is indicated in broken
line table,users can purchase the wired controller when
necessary
7.1 Terminal Board Diagram
Please refer to the indoor unit wiring diagram for the wiring.
NOTE
The air-conditioners can be connected with Central Control
Monitor (CCM). Before operation, please wiring correctly and
set system address and network address of indoor units.
Single phase indoor unit
INDOOR UNIT POWER
220-240V
̚
̚
50/60Hz
(Conventional)
XT1
Y/G
Y/G
RED
BLACK
/ 1
RED
BLACK
RED
BLUE
To central control
Monitor (CCM)
COMM. BUS
To outdoor
COMM. BUS
Please adopt the 3-core shielded wire.
7.2 Capacity setting
Horsepower code
Code
Capacity (HP)
0
1
2
3
4
2200W(0.8HP)
5600W(2.0HP)
4500W(1.5HP)
3600W(1.2HP)
2800W(1.0HP)
5
7100W(2.5HP)
Note: The horsepower
has been set before
leaving the factory ,
anyone can
̓
t
modify it except the
maintenance person.
1
2
3
4
5
67
8
9A
B
C
D
E
F
0
ENC1
POWER_S
Setting
Toggle switch
ENC1
6
7
8000W(3.0HP)
9000W(3.2HP)
<(//2:
*5$<
P
Q
X
Y (E)
;7
:+,7(
%/8(
%/$&.
The system together have 64units(0-63), everyone has only
system addresscode,If two addresses are the same in one
system, the abnormal operation will occur.
CAUTION
Installation manual
Wall mounted split D4+
8