background image

To install properly, please read this "installation manual" at 
first.

The air conditioner must be installed by qualified persons.

When installing the indoor unit or its tubing, please follow 
this manual as strictly as possible.

If the air conditioner is installed on a metal part of the 
building, it must be electrically insulated according to the 
relevant standards to electrical appliances.

When all the installation work is finished, please turn on the 
power only after a thorough check.

Regret for no further announcement if there is any change 
of this manual caused by product improvement.

2.    INSTALLATION INFORMATION

INSTALLATION ORDER

Select the location;

Install the indoor unit;

Install the outdoor unit;

Install the connecting pipe ;

Connect the drain pipe;

Wiring;

Test operation.

CAUTION

Ground the air conditioner.

Do not connect the ground wire to gas or water pipes, 
lightning rod or a telephone ground wire.Incomplete 
grounding may result in electric shocks.

Be sure to install an earth leakage breaker.

Failure to install an earth leakage breaker may result in 
electric shocks.

Connect the outdoor unit wires , then connect the indoor 
unit wires.

 

You are not allow to connect the air conditioner with the 
power source until w(including 
iring and piping the air conditioner is done.

While following the instructions in this installation 
manual, install drain piping in order to ensure proper 
drainage and insulate piping in order to prevent 
condensation.

Improper drain piping may result in water leakage and 
property damage.

Install the indoor and outdoor units, power supply wiring 
and connecting wires at least 1 meter away from 
televisions or radios in order to prevent image 
interference or noise.

Depending on the radio waves, a distance of 1 meter may not 
be sufficient enough to eliminate the noise.

The appliance is not intended for use by young children 
or infirm persons without supervision.

Young children should be supervised to ensure that they 
do not play with the appliance

.

Don't install the air conditioner in the following locations:

There is petrolatum existing.

There is salty air surrounding (near the coast).

There is caustic gas (the sulfide, for example) existing in 
the air (near a hot spring).

The Volt vibrates violently (in the factories).

In buses or cabinets.

In kitchen where it is full of oil gas.

There is strong electromagnetic wave existing.

There are inflammable materials or gas.

There is acid or alkaline liquid evaporating.

The appliance shall not be installed in the laundry.

Other special conditions.

If the refrigerant leaks during installation, ventilate the 
area immediately.

Toxic gas may be produced if the refrigerant comes into the 
place contacting with fire.

After completing the installation work, check that the 
refrigerant does not leak.

Toxic gas may be produced if the refrigerant leaks into the 
room and comes into contact with a source of fire, such as a 
fan heater, stove or cooker.

̚

Installation manual

Wall mounted split D4+

2

Содержание CL23215

Страница 1: ... MVD Installation manual English CL23215 to CL23217 Wall Mounted Split www mundoclima com www mundoclima com ...

Страница 2: ... to let air substances go into refrigeration cycle Otherwise it will cause lower capacity abnormal high pressure in the refrigeration cycle explosion and injury Do not modify the length of the power supply cord or use of extension cord and do not share the single outlet with other electrical appliances Otherwise it will cause fire or electrical shock Carry out the specified installation work after...

Страница 3: ...sure proper drainage and insulate piping in order to prevent condensation Improper drain piping may result in water leakage and property damage Install the indoor and outdoor units power supply wiring and connecting wires at least 1 meter away from televisions or radios in order to prevent image interference or noise Depending on the radio waves a distance of 1 meter may not be sufficient enough t...

Страница 4: ...apart from the nearest TV set or stereo equipment it is necessary to prevent image disturbances or noise interferences Do not install the remote controller in a place exposed to direct sunlight or close to a heating source such as a stove Note that the positive and negative poles are right positions when loading batteries This manual is subject to changes due to technological improvement without f...

Страница 5: ...of the room is perfect The indoor unit should be installed 2 5 meters or more above the floor Installation in the following places may cause trouble If it is unavoidable please consult with the local dealer A place full of machine oil A saline place such as coast A place full of sulfide gas such as hot spring resort Places where there are high frequency machines such as wireless equipment welding ...

Страница 6: ...n the outdoor unit and bend and arrange the pipe carefully Do not allow the piping to let out from the back of the indoor unit Be careful not to let the drain hose slack Insulate both of the auxiliary piping Banding the drain hose under the auxiliary pipe Do not allow the piping to let out from the back of the indoor unit 43 Indoor unit outline Connective pipe Fix the end of the connective pipe Re...

Страница 7: ...Double span should be used when connecting pipesof Indoor Unit Table 6 1 NOTE Please refer to installation instructions for the refrigerant piping conection of the air conditioner that with throttle device inside Tightening Torque Φ6 4 Outer diameter mm of connection piping Φ9 5 Tightening Torque N m 32 7 39 9 Φ15 9 61 8 75 4 Φ19 1 97 2 118 6 14 2 17 2 Table 6 2 Φ12 7 49 5 60 3 Fig 5 9 Fig 5 10 Co...

Страница 8: ...iring according to the nati onal rule CAUTION Model W 7100 9000 16 10 8A 3x2 5 Manual switch Insurance A Indoor unit power wiring mm2 Indoor outdoor connecting wiring mm2 3 core shielded wire Power Phase Fuse A 1 Phase 220 240V 50 60Hz Frequency and volt 3x0 75 3 4 3 4 Signal wire for communicate outdoor unit Connect all shielding layer of the shielding wires Signal wire for communicate indoor uni...

Страница 9: ...XT1 Y G Y G RED BLACK 1 RED BLACK RED BLUE To central control Monitor CCM COMM BUS To outdoor COMM BUS Please adopt the 3 core shielded wire 7 2 Capacity setting Horsepower code Code Capacity HP 0 1 2 3 4 2200W 0 8HP 5600W 2 0HP 4500W 1 5HP 3600W 1 2HP 2800W 1 0HP 5 7100W 2 5HP Note The horsepower has been set before leaving the factory anyone can t modify it except the maintenance person 1 2 3 4 ...

Страница 10: ...ping fan is 12 minutes Ș 11 means the time of stopping fan is 16 minutes 6 21 6 21 6 21 6 21 6 21 6 21 6 21 6 21 6 definition Ș 00 means temperature compensation is 6 degrees under heating mode Ș 10 means temperature compensation is 4 degrees under heating mode Ș 11 means temperature compensation is 8 degrees under heating mode Ș 01 means temperature compensation is 2 degrees under heating mode 6 ...

Страница 11: ...eted The refrigerant pipe system is leakage checked The drainage is unimpeded The heating insulation works well The ground wiring is connected correctly According to the user s requirement install the remote controller frame where the remote controller s signal can reach the indoor unit smoothly Test operation Set the air conditioner under the mode of COOLING with the remote controller and check t...

Страница 12: ... ASK FOR MORE INFORMATION Phone 34 93 446 27 80 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 MVD www mundoclima com ...

Отзывы: