background image

When installing the unit in a small room, take measures 
against to keep refrigerant concentration from exceeding 
allowable safety limits in the event of refrigerant leakage.

 

Contact the place of purchase for more information. 
Excessive refrigerant in a closed ambient can lead to oxygen 
deficiency.

Use the attached accessories parts and specified parts 
for installation. 

otherwise, it will cause the set to fall, water  leakage, 
electrical shock fire.

Install at a strong and firm location which is able to 
withstand the set' s weight. 

If the strength is not enough or installation is not properly 
done, the set will drop to cause injury.

The appliance must be installed 2.5m above floor.

The appliance shall not be installed in the laundry.

Before obtaining access to terminals, all supply circuits 
must be disconnected.

The appliance must be positioned so that the plug is 
accessible.

The enclosure of the appliance shall be marked by word, 
or by symbols, with the direction of the fluid flow.

For electrical work, follow the local national wiring 
standard, regulation and this installation instructions. An 
independent circuit and single outlet must be used. 

If electrical circuit capacity is not enough or defect in 
electrical work, it will cause electrical shock fire.

Use the specified cable and connect tightly and clamp 
the cable so that no external force will be acted on the 
terminal.

 

If connection or fixing is not perfect, it will cause heat-up or 
fire at the connection.

Wiring routing must be properly arranged so that control 
board cover is fixed properly. 

If control board cover is not fixed perfectly, it will cause 
heat-up at connection point of terminal, fire or electrical 
shock.

If the supply cord is damaged, it must be replaced by the 
manufacture or its sevice agent or similarly qualifued 
person in order to avoid a hazard.

An all-pole disconnection switch having a cintract 
separation of at least 3mm in a  poles should be 
connected in fixed wiring.

When carrying out piping connection, take care not to let 
air substances go into refrigeration cycle. 

Otherwise, it will cause lower capacity, abnormal high 
pressure in the refrigeration cycle, explosion and injury.

Do not modify the length of the power supply cord or use 
of extension cord, and do not share the single outlet with 
other electrical appliances. 

Otherwise, it will cause fire or electrical shock.

Carry out the specified installation work after taking into 
account strong winds, typhoons or earthquakes.

Improper installation work may result in the equipment falling 
and causing accidents.

Be sure to be in conformity with the local, national and 
international laws and regulations.

Read "PRECAUTIONS" carefully before installation.

The following precautions include important safty items. 
Observe them and never forget.

Keep this manual with the owner's manual in a handy place 
for future reference.

Installation must be performed in accordance with the 
requirement of NEC and CEC by authorized personnel only.

1.    PRECAUTIONS

WARNING

WARNING

The safty precautions listed here are divided into two categories. In 
either case, important safty information is listed which must be read 
carefully.

After completing the installation, make sure that the unit operates 
properly during the start-up operation. Please instruct the customer 
on how to operate the unit and keep it maintained.Also, inform 
customers that they should store this installation manual along with 
the owner's manual for future reference.  

Be sure only trained and qualified service personnel to 
install, repair or service the equipment.

Improper installation, repair, and maintenance may result in 
electric shocks, short-circuit, leaks, fire or other damage to 
the equipment.

Install according to this installation instructions strictly. 

If installation is defective, it will cause water leakage, electric 
shocks, fire.

Failure to observe a warning may result in death.

CAUTION

Failure to observe a caution may result in injury or damage 
to the equipment.

CONTENTS

PAGE

PRECAUTIONS........................................................................................1
INSTALLATION INFORMATION................................................................2
ATTACHED FITTINGS..............................................................................3
INSPECTING AND HANDLING THE UNIT................................................ 4
INDOOR UNIT INSTALLATION................................................................ 4
REFRIGERANT PIPE INSTALLATION....................................................... 6
WIRING CHART..............................................................................7
TEST OPERATION..................................................................................10

̚

Installation manual

Wall mounted split D4+

1

Содержание CL23215

Страница 1: ... MVD Installation manual English CL23215 to CL23217 Wall Mounted Split www mundoclima com www mundoclima com ...

Страница 2: ... to let air substances go into refrigeration cycle Otherwise it will cause lower capacity abnormal high pressure in the refrigeration cycle explosion and injury Do not modify the length of the power supply cord or use of extension cord and do not share the single outlet with other electrical appliances Otherwise it will cause fire or electrical shock Carry out the specified installation work after...

Страница 3: ...sure proper drainage and insulate piping in order to prevent condensation Improper drain piping may result in water leakage and property damage Install the indoor and outdoor units power supply wiring and connecting wires at least 1 meter away from televisions or radios in order to prevent image interference or noise Depending on the radio waves a distance of 1 meter may not be sufficient enough t...

Страница 4: ...apart from the nearest TV set or stereo equipment it is necessary to prevent image disturbances or noise interferences Do not install the remote controller in a place exposed to direct sunlight or close to a heating source such as a stove Note that the positive and negative poles are right positions when loading batteries This manual is subject to changes due to technological improvement without f...

Страница 5: ...of the room is perfect The indoor unit should be installed 2 5 meters or more above the floor Installation in the following places may cause trouble If it is unavoidable please consult with the local dealer A place full of machine oil A saline place such as coast A place full of sulfide gas such as hot spring resort Places where there are high frequency machines such as wireless equipment welding ...

Страница 6: ...n the outdoor unit and bend and arrange the pipe carefully Do not allow the piping to let out from the back of the indoor unit Be careful not to let the drain hose slack Insulate both of the auxiliary piping Banding the drain hose under the auxiliary pipe Do not allow the piping to let out from the back of the indoor unit 43 Indoor unit outline Connective pipe Fix the end of the connective pipe Re...

Страница 7: ...Double span should be used when connecting pipesof Indoor Unit Table 6 1 NOTE Please refer to installation instructions for the refrigerant piping conection of the air conditioner that with throttle device inside Tightening Torque Φ6 4 Outer diameter mm of connection piping Φ9 5 Tightening Torque N m 32 7 39 9 Φ15 9 61 8 75 4 Φ19 1 97 2 118 6 14 2 17 2 Table 6 2 Φ12 7 49 5 60 3 Fig 5 9 Fig 5 10 Co...

Страница 8: ...iring according to the nati onal rule CAUTION Model W 7100 9000 16 10 8A 3x2 5 Manual switch Insurance A Indoor unit power wiring mm2 Indoor outdoor connecting wiring mm2 3 core shielded wire Power Phase Fuse A 1 Phase 220 240V 50 60Hz Frequency and volt 3x0 75 3 4 3 4 Signal wire for communicate outdoor unit Connect all shielding layer of the shielding wires Signal wire for communicate indoor uni...

Страница 9: ...XT1 Y G Y G RED BLACK 1 RED BLACK RED BLUE To central control Monitor CCM COMM BUS To outdoor COMM BUS Please adopt the 3 core shielded wire 7 2 Capacity setting Horsepower code Code Capacity HP 0 1 2 3 4 2200W 0 8HP 5600W 2 0HP 4500W 1 5HP 3600W 1 2HP 2800W 1 0HP 5 7100W 2 5HP Note The horsepower has been set before leaving the factory anyone can t modify it except the maintenance person 1 2 3 4 ...

Страница 10: ...ping fan is 12 minutes Ș 11 means the time of stopping fan is 16 minutes 6 21 6 21 6 21 6 21 6 21 6 21 6 21 6 21 6 definition Ș 00 means temperature compensation is 6 degrees under heating mode Ș 10 means temperature compensation is 4 degrees under heating mode Ș 11 means temperature compensation is 8 degrees under heating mode Ș 01 means temperature compensation is 2 degrees under heating mode 6 ...

Страница 11: ...eted The refrigerant pipe system is leakage checked The drainage is unimpeded The heating insulation works well The ground wiring is connected correctly According to the user s requirement install the remote controller frame where the remote controller s signal can reach the indoor unit smoothly Test operation Set the air conditioner under the mode of COOLING with the remote controller and check t...

Страница 12: ... ASK FOR MORE INFORMATION Phone 34 93 446 27 80 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 MVD www mundoclima com ...

Отзывы: