background image

5. Select the required output protocol from the menu.
6. Open the housing again and place the jumper back in it’s opened position.
7. Close the housing.

Jumper Opened    Jumper Closed

Once in the programming mode (step 5) you have the following menu at your disposal:

1 + A

: WIEGAND 26 bit protocol selected

2 + A

: WIEGAND 30 bit protocol selected

3 + A

: DATA/CLOCK protocol selected

4 + A

: CODIX bus protocol selected

  Note that this only needs to be done once during initialization. Once this operation is done the user will 
obtain the programming menus as described below.

  Note: If programming for WIEGAND or DATACLOCK format is continued immediately after the 
selection of the protocol you only need to open and close consecutively the housing of the keypad. You
can continue immediately with step 5 in the programming menus of the selected protocol.

3.2 WIEGAND 26 bit format

3.2.1 Programming Jumper

  The programming jumper allows the user to modify several code features sent by the MONO-S to 
comply with the specific needs of the host and to increase the overall security level of the system.

  A fixed header (from 0 to 255) can be added to the 26-bit WIEGAND output with this jumper. This 
header may be used as a site code. Security is increased when the host control unit can be programmed 
in such a way that no readers can be accepted unless they have this fixed header

  On the other hand, it is possible to reduce the number of codes that can be sent to the host in case 
there is limited available memory space. This prevents any coincidental interference between the codes 
sent out by the MONO-S and the codes already in the system's memory. For example the host control 
unit can see the keypad code 5 as a magstripe card with code 5.

3.2.2 Entering the programming mode

1. Open the keypad housing.
2. Place the jumper in it’s closed position.
3. Close the housing
4. A long beep will be heard and the Yellow LED will light up. Wait until the beep stops. This should 

take about 4 seconds.

5. Select the correct settings from the menu below.
6. Open the keypad housing and place the jumper back in it’s opened position.
7. Close the housing.

Jumper Opened    Jumper Closed

6

Содержание MONO-S

Страница 1: ......

Страница 2: ...Activation of mode 10000 65535 3 2 2 5 Return to default settings 3 2 3 Data output from the MONO S in 26 bit WIEGAND format 3 3 WIEGAND 30 bit format 3 3 1 Programming Jumper 3 3 2 Entering the progr...

Страница 3: ...correct functioning of the communication bus and valid invalid codes 1 BUZZER indicates programming state correct functioning of the communication bus and valid invalid codes 2 1 Mounting instruction...

Страница 4: ...imum recommended cable length between 2 MONO S keypads is 100 metres and between power supply and the MONO S is 50 metres Make sure the tamper switch on the rear panel of the MONO S keypad is making d...

Страница 5: ...per switch The tamper switch is a security contact NC to detect the opening or tampering of the housing Once the keypad is installed against the wall the contact remains closed MONO S features double...

Страница 6: ...S to comply with the specific needs of the host and to increase the overall security level of the system A fixed header from 0 to 255 can be added to the 26 bit WIEGAND output with this jumper This h...

Страница 7: ...ted only the codes from 4 to 5 digits between 1000 and 65535 are sent to the host system In programming mode when Yellow LED is on press 4 A to activate 3 2 2 4 Activation of mode 10000 65535 Once thi...

Страница 8: ...nd place the jumper back in it s opened position 7 Close the housing Jumper Opened Jumper Closed Once in the programming mode step 5 you have the following menu at your disposal 0 Group number A Progr...

Страница 9: ...ill not If the user enters a code with 7 or more digits A key not included an error signal beep beep beep will be heard Note that shorter codes are completed with zeros at the beginning to obtain the...

Страница 10: ...he entire 10 digits excluding the parity bit Characters are encoded with the least significant bit first 3 5 CODIX format There is no further programming menu for the MONO S with CODIX format In the p...

Страница 11: ...be transferred to the host system Warranty XPR warrants its products to be free from defects in material and workmanship for 24 months from the date of shipment The product is to be installed in acco...