background image

CONTENTS

1.0

Introduction

1.1

Specifications

2.0

Mounting and wiring instructions

2.1

Mounting instructions

2.2

Wiring instructions

2.3

Bus connection

2.3.1

CODIX format

2.3.2

WIEGAND format

2.3.3

DATA/CLOCK format 

2.4

Connection of the RED Free-tension LED on a 12V AC/DC Source

3.0

Programming of the MONO-S

3.1

Selecting the output protocol

3.1.1

Entering the programming mode

3.2

WIEGAND 26 bit format

3.2.1

Programming Jumper

3.2.2

Entering the programming mode

3.2.2.1 Programming the site code
3.2.2.2 Activation of mode 0-65535
3.2.2.3 Activation of mode 1000-65535
3.2.2.4 Activation of mode 10000-65535
3.2.2.5 Return to default settings
3.2.3

Data output from the MONO-S in 26-bit WIEGAND format

3.3

WIEGAND 30 bit format

3.3.1

Programming Jumper

3.3.2

Entering the programming mode

3.3.3

Data output from the MONO-S in 30 bit WIEGAND format

3.4

DATA/CLOCK format

3.4.1

Entering the programming mode

3.4.2

Selecting the maximum number of digits sent to the host

3.4.3

Functioning in security mode

3.4.4

Return to default settings

3.4.5

Data output from the MONO-S in DATA/CLOCK format

3.5

CODIX format

4.0

Visual (Yellow LED) and audible signals

4.1

MONO-S CODIX version

4.2

MONO-S WIEGAND and DATA/CLOCK version

5.0

Using the MONO-S keypad

2.5

Connecting Tamper switch

2

3

3

3

3
4
4
4
5
5
5
5

5

5
5
6
6
6
7
7
7
7
7
7
8
8
8
8
9
9
9
9
10
10
10

10

10
10

11

Содержание MONO-S

Страница 1: ......

Страница 2: ...Activation of mode 10000 65535 3 2 2 5 Return to default settings 3 2 3 Data output from the MONO S in 26 bit WIEGAND format 3 3 WIEGAND 30 bit format 3 3 1 Programming Jumper 3 3 2 Entering the progr...

Страница 3: ...correct functioning of the communication bus and valid invalid codes 1 BUZZER indicates programming state correct functioning of the communication bus and valid invalid codes 2 1 Mounting instruction...

Страница 4: ...imum recommended cable length between 2 MONO S keypads is 100 metres and between power supply and the MONO S is 50 metres Make sure the tamper switch on the rear panel of the MONO S keypad is making d...

Страница 5: ...per switch The tamper switch is a security contact NC to detect the opening or tampering of the housing Once the keypad is installed against the wall the contact remains closed MONO S features double...

Страница 6: ...S to comply with the specific needs of the host and to increase the overall security level of the system A fixed header from 0 to 255 can be added to the 26 bit WIEGAND output with this jumper This h...

Страница 7: ...ted only the codes from 4 to 5 digits between 1000 and 65535 are sent to the host system In programming mode when Yellow LED is on press 4 A to activate 3 2 2 4 Activation of mode 10000 65535 Once thi...

Страница 8: ...nd place the jumper back in it s opened position 7 Close the housing Jumper Opened Jumper Closed Once in the programming mode step 5 you have the following menu at your disposal 0 Group number A Progr...

Страница 9: ...ill not If the user enters a code with 7 or more digits A key not included an error signal beep beep beep will be heard Note that shorter codes are completed with zeros at the beginning to obtain the...

Страница 10: ...he entire 10 digits excluding the parity bit Characters are encoded with the least significant bit first 3 5 CODIX format There is no further programming menu for the MONO S with CODIX format In the p...

Страница 11: ...be transferred to the host system Warranty XPR warrants its products to be free from defects in material and workmanship for 24 months from the date of shipment The product is to be installed in acco...

Отзывы: