33
Software Installation
If the station device uses ground start, then choose the
FXS (Ground Start)
option. Refer to the device’s user
documentation.
If you are using an extension from your PBX, then choose
the
FXO
option. Check with your in-house telephone
personnel to verify connection type.
If you are connecting to an E&M trunk on your PBX, select
the
E&M
option.
If the
E&M
interface is selected, the E&M Options group is
enabled. Check with your in-house phone personnel to
determine if the signaling is
Dial Tone
or
Wink
and if the
connection is 2-wire or 4-wire. If Wink signaling is used,
then the
Wink Timer
is enabled with a default of 250
milliseconds. The range of the Wink Timer is from 100 to
350 milliseconds. Consult with your local in-house phone
personnel for this timer setting. If the
Pass Through
check box is selected, a continuously open E&M voice
path is established between two channels to pass voice
packets. Available if the
Dial Tone
option is selected and
auto-dialing is set up for the two channels that will be
doing pass-through. This is useful for Public Address
systems.
If you choose an
FXO
or
FXS
interface, the Dialing
Options Regeneration group is enabled. Check with your
in-house telephone personnel to verify whether your local
PBX dial signaling is
Pulse
or
DTMF
(tone). Set the
Regeneration option accordingly. In the
Max Dial Digits
box, enter the maximum number of digits allowed when
dialing a phone number. The default setting is 5. In the
Inter Digit Time
box, enter the maximum amount of time
in milliseconds that the unit will wait before mapping the
dialed digits to an entry in the Phone Directory Database.
If too much time elapses between digits and the wrong
numbers are mapped, you hear a rapid busy signal. If this
happens, hang up and dial again. This option is available
Содержание MultiVOIP 400 MVP400