background image

Chapter 1 – Product Description and Specifications  

Multi-Tech Systems, Inc. MultiConnect AW User Guide 

 

 

Front Panel 

The front panel is designed with a Power indicator and four Dial indicators on both models. The MT100A2W-G model 
also has five wireless modem LEDs, three Signal strength LEDs, and a SIM door. The Power LED lights when power 
is applied to the unit. The four analog signal LEDs (Dial) display the activity of the analog modem port.  The five 
wireless modem LEDs display the activity of the internal wireless modem and the three Signal strength LEDs display 
the signal strength level of the internal wireless connection on the MT100A2W-G model. The SIM door on the right 
side provides access to the SIM card holder for the MT100A2W-G model. 

 

MT100A2W-G 

 

MT100A2W 

LEDs 

 

 

LED Indicators 

Power 

Indicates presence of DC power when lit.

 

Analog 
Modem 
Port 

TD 

– 

Transmit Data

 – Flashes when the analog modem port is transmitting data.  

RD 

– 

Receive Data

 – Flashes when the analog modem port is receiving data. 

CD 

-Carrier Detect.

 Lit when the data connection from the analog modem port is established.

 

OH 

– Off-hook – 

Lit when the analog modem port goes off-hook 

Internal 

Wireless 

Modem 

 

TD 

– 

Transmit Data

 – Flashes when the wireless modem is transmitting data.  

RD 

– 

Receive Data

 – Flashes when wireless modem is receiving data. 

TR 

- Terminal Ready – 

Lit indicates the communication channel between the internal processor 

and the internal wireless modem is ready. 

LS

 - Link Status. 

  Off - 

Unit is off or not registered on network. 

 

Continuous “ON” - 

Indicates that the wireless modem is not registered on the network. 

  Slow Flash * - 

Indicates registration on network. 

     Quick Flash ** –

 Indicates registration on the network and communication is in progress.

 

Signal 

ALL OFF - 

Unit is off, not registered on network, or extremely week signal (RSSI <7). 

 

1 Bar

 “

ON

” – Very weak signal (7 < = RSSI <12) 

1 Bar

 and 

2 Bar

 “

ON

” – Week signal (12 < = RSSI <12) 

1 Bar

2 Bar

, and 

3 Bar

 “

ON

” – Good signal ( RSSI > = 15)

 

Package Contents 

 

1 MultiConnect Converter 

 

1 antenna 

 

1 RS232 cable 

 

1 power supply  

 

1 Quick Start Guide 

 

1 MultiConnect CD 

 

 

Note: You must supply mounting screws. 

Note:

  

Your wireless provider will supply the SIM card.

 

Interfaces 

The MultiConnect has several interfaces: 

 

LED function indicating operating status 

 

External antenna (via SMA connector) 

 

Serial port (Command) for configuration (via 9-pin DE9 female) 

 

Dial port (via RJ11)  

 

Modem port (via 9-pin DE9 male) (MT100A2W model only) 

 

Power supply (via 2.5mm miniature power jack) 

 

SIM card holder (MT100A2W-G model only) 

 

 

Содержание MultiConnect MT100A2W

Страница 1: ...MultiConnect AW Analog to Wireless Converter User Guide...

Страница 2: ...n or organization of such revisions or changes Check Multi Tech s Web site for current versions of our product documentation Revision History Revision Date Description A 07 20 09 Initial Release Trade...

Страница 3: ...onal Attach the Modem to a Flat Surface 12 CHAPTER 3 CONFIGURATION OF YOUR MULTICONNECT 13 Login 14 Device Configuration 15 Cellular Port Configuration 16 CHAPTER 4 DEVICE CONFIGURATION 19 GPRS Cellul...

Страница 4: ...d external modem for the cellular connection Both models are housed in a rugged metal chassis The MultiConnect AW converter operates on standards based communication networks and can be desktop or pan...

Страница 5: ...where blasting operations are in progress There may be a hazard associated with the operation of your MultiConnect close to inadequately protected personal medical devices such as hearing aids and pac...

Страница 6: ...es off hook Internal Wireless Modem TD Transmit Data Flashes when the wireless modem is transmitting data RD Receive Data Flashes when wireless modem is receiving data TR Terminal Ready Lit indicates...

Страница 7: ...5A 32V Peak 0 50A Dimensions 7 W x 1 24 H x 2 79 D 78lbs 17 78cmW x 3 15cmH x 7 07cmD 0 320Kg Operating Temperature 40 C to 60 C UL listed 40 C Storage Temperature 40 C to 85 C Humidity Relative humid...

Страница 8: ...y Relative humidity 20 to 90 noncondensing Compliance EMC Compliance FCC Part 15 EN55022 EN55024 Safety UL60950 1 cUL60950 1 EN60950 1 Multi Tech Systems Inc recommends that the customer incorporate a...

Страница 9: ...RA Hinged Right Angle 800 1900 MHz Cellular Modem Antenna ANF21HRA Hinged Right Angle 850 900 1800 1900 MHz Cellular Modem Antenna ANQB 1HRA PTCRB Requirements Note There cannot be any alteration to t...

Страница 10: ...es the power supply connection to begin operation It also requires a SIM card Subscriber Identity Module in the MT100A2W G unit to operate on a GPRS GSM network To install the SIM do the following 1 U...

Страница 11: ...nect the other end of the cable to your external wireless modem 4 Connect the RJ 11 phone cable to the DIAL connector on the unit and connect the other end of the phone cable to the customer s analog...

Страница 12: ...al Attach the Modem to a Flat Surface The modem can be panel mounted with screws spaced according to the measurement shown Note Use either 4 or 6 pan head screws for all four mount locations Multi Tec...

Страница 13: ...following configuration procedures are based on the Windows XP Operating System Other Windows operating systems have similar paths to HyperTerminal See your system s online Help if you cannot find it...

Страница 14: ...Properties screen is displayed Change the default Bits per second window from 2400 to 115200 Click the Apply button and then OK Login 1 The Login screen is displayed Enter the default password of admi...

Страница 15: ...nge is in Option 1 which in the Current Settings displays the cellular network type GPRS or GSM for the MT100A2W G unit or CDMA for the MT100A2W unit The GPRS cellular network is for packet switched d...

Страница 16: ...ort menu is displayed 2 Configure options A thru D for your GPRS cellular network GPRS Network Dependent Option Default Description A GPRS or GSM GPRS Select GPRS B Protocol TCPClient Select either TC...

Страница 17: ...t for the cellular wireless network and the analog modem to change to a READY state The Current Settings will change to State WIRELESS_READY State ANALOG_READY Initial configuration of the GPRS versio...

Страница 18: ...and Select either OnDemand or Always On ATTENTION If Always On is desired wait until you have made all your other configuration changes before selecting this option 3 When you change the Remote Port o...

Страница 19: ...t G Remote IP J View or change Phone Number IP Conversion Table K Wireless Band L APN User Name M APN Password N APN Server O Phy TimeOut Min P DLE Mode Q TCP TxDelay R HandShake TimeOut sec Z Enter W...

Страница 20: ...sion for acknowledgement of packets received 4 PassThru option allows for data to be transferred from a legacy device to a remote destination without being modified C Inbound Outbound Outbound 0 Auto...

Страница 21: ...is used For detail instructions on entering data in this table refer to View or Change Phone Number IP Conversion Table in this chapter Wireless Band Option Default Selection K Wireless Band This opti...

Страница 22: ...means a request or an indication of end of correction As a consequence EXT characters that belong to the payload must be sent by the host on the serial port preceded by a DLE character Similarly EXT c...

Страница 23: ...ireless Band Option Default Selection K Wireless Band This option is default depending on the region of the world the unit is set up for e g 850 1900MHz for NAM 0 dual band 850 1900 MHz 1 dual band 90...

Страница 24: ...rotocol in that UDP makes no provision for acknowledgement of packets received 4 PassThru option allows for data to be transferred from a legacy device to a remote destination without being modified C...

Страница 25: ...emote IP it becomes the new default IP Phone Number IP Conversion Table Option Default Selection J View or change Phone Number IP Conversion Table This option allows for additional connections to be a...

Страница 26: ...nge and press ENTER Enter Server Port Number ESC to abort Enter a numerical port number and press ENTER Enter Server Phone Number ESC to abort Enter the telephone number without the dashes between the...

Страница 27: ...o enter initialization commands into the internal analog modem B Modem Settings V34 33600 The Modem Settings option allows you to reconfigure the internal analog modem By selecting option B a submenu...

Страница 28: ...dulation options are A V92 B V90 C V34 D V32bis E V32 F V22bis G V22 H BELL212A I BELL103 C Error Correction V 42 MNP Error Correction options are A V 42 MNP B V 42 Only C MNP Only D Direct Mode E NoE...

Страница 29: ...ng into the device B Login Required Login Required option requires that you login to the MultiConnect AW before gaining access to the device C Change PassWord The Change PassWord option allows you to...

Страница 30: ...h no activity This inactivity time is displayed in seconds Zero seconds disables the timer B No Signal Reset Timer 300 sec The MultiConnect AW resets itself if it can not find a signal strong enough t...

Страница 31: ...il server B SMTP PW The SMTP Pass Word PW option is the pass word of the email server C SMTP PORT The SMTP Port is the port that the email server listens on The default port number is 25 D SMTP Authen...

Страница 32: ...meters to Default Option Description Are you sure you want to reset ALL parameters back to Defaults This option requires either a yes or no You have to enter the word not just a letter y n Multi Tech...

Страница 33: ...hapter 4 Device Configuration System Reboot Option Description Are you sure you want to reboot the unit This option requires either a yes no or y n Multi Tech Systems Inc MultiConnect AW User Guide 33...

Страница 34: ...de reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance wit...

Страница 35: ...of specified percentages per the WEEE requirements Instructions for Disposal of WEEE by Users in the European Union The symbol shown below is on the product or on its packaging which indicates that th...

Страница 36: ...MII EIP 39 RoHS Multi Tech Systems Inc TS HS PB Hg CD CR6 PBB PBDE O O O O O O X O O O O O X O O O O O O O O O O O O O O O O O IC O O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O...