background image

CC9600 Chassis User Guide

10

CommPlete Communications Server

Appendix A   Installing 3rd Party Software

This appendix describes how to install the following software packages on the CommPlete Communication
Server:

 

Citrix

 WinFrame

 

Microsoft

 Windows

 NT

 

SCO

 UNIX

 

Novell

 UNIXWare

 

BSD

 UNIX

These procedures can be performed only by using the optional DA96002 load card.

SCO UNIX, UNIXWare, and BSD UNIX procedures to be added later.

Installing Citrix

 WinFrame

 Software on the CommPlete

This procedure tells how to install the Citrix

 WinFrame

 software package on the CommPlete

Communication Server.  This procedure can be performed only by using the optional DA96002 load card.

 

1.

 

Start the Citrix install procedures (refer to the applicable Citrix WinFrame documentation).

 

2.

 

When the CommPlete system is back running, copy the I386 directory from the Citrix CD to the root
directory of the CommPlete’s hard drive.

 

3.

 

Copy the ISI608 driver disk to the root directory of the CommPlete’s hard drive.

 

4.

 

Install any software that you need which requires the CD-ROM drive or the floppy drive.

 

5.

 

Remove the IDE CD-ROM from the system.  At the main menu, select “Winframe setup”.  Under
“Options”, select “Add/Remove SCSI devices”. Highlight “IDE CD-ROM drive” and click on
“Remove”.

 

6.

 

At the Control panel, select “Devices”.  Highlight the atdisk device.  Select the Startup button and
click on “BOOT”.  This will put a circle in the boot section.

 

7.

 

Exit the menus and shutdown the CommPlete system.

 

8.

 

Remove the RASCard, MT3334HD8 modems, and remove the DA9600 card and cables.

 

9.

 

Re-install the RASCard and MT3334HD8 modem cards.

 

10.

 

Restart the CommPlete system.

 

11.

 

Install the ISI608 drives.  Under the Main menu, select “Control Panel” and then select
“Networking”.

 

12.

 

Select “Add new adapter”.

 

13.

 

At the bottom of the list select “Disk from manufacturer”.

 

14.

 

Enter the path for the ISI608 drivers (e.g., “c:\isi608\winnt\”).  The system will start installing the
drivers.  The message box “How many cards?” is displayed.

 

15.

 

Select “Three” cards.  A prompt will ask for the I/O address and IRQ of the first card.

Содержание CommPlete CC9600

Страница 1: ...CC9600 Chassis User Guide ...

Страница 2: ...thout obligation of Multi Tech Systems Inc to notify any person or organization of such revisions or changes Revision Date Description A B 3 31 97 5 27 97 Manual released Manual updated C 11 17 97 Manual revised to include new FCC information and removal of service information Multi Tech CommPlete RASExpress MultiExpress MultiExpress Fax MultiModem MultiModemZDX MultiModemManager and the Multi Tec...

Страница 3: ...Service Order Code connecting arrangement for this equipment is shown If applicable the facility interface codes FIC and service order codes SOC are shown A FCC compliant telephone cord and modular plug is provided with this equipment This equipment is designed to be connected to the telephone network or premises wiring using a compatible modular jack which is Part 68 compliant See installation in...

Страница 4: ...2205 Woodale Drive Mounds View MN 55112 612 785 3500 Fax 612 785 9874 FCC Fax Warning The Telephone Consumer Protection Act of 1991 makes it unlawful for any person to use a computer or other electronic device to send any message via a telephone fax machine unless such message clearly contains in a margin at the top or bottom of each page or the first page of the transmission the date and time it ...

Страница 5: ...the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users should not attempt to make such connections themselves but should contact the appropriate ele...

Страница 6: ... déconnexion Les prises d alimentation doyent être installées près de l équipement et doyent être faciles d accès Afin de réduire les risques de choc toutes les ouvertures doivent être couvertes pendant le fonctionnement normal de l équipement Advertencias de Seguridad No son necesarios ajustes manuales del equipo para la conexión a la corriente de la red dentro del voltaje y frecuencia establecid...

Страница 7: ...gsledningen er beregnet til at fungere som afbryder Stikkontakten skal installeres nær ved udstyret og skal være let tilgængelig Nedsæt risikoen for stød ved at tildække alle udstyrets åbninger under normal drift Power Requirements AC 100 240 V 50 60 Hz 8 A Alimentation Requise AC 100 240V 50 60 Hz 8 A Requisitos de potencia AC 100 240V 50 60 Hz 8 A Stromaufnahme AC 100 240V 50 60 Hz 8 A Strømfors...

Страница 8: ...viii CommPlete Communications Server ...

Страница 9: ...lation Notes 6 Installation 7 Safety Warnings 7 Connections 8 Appendix Appendix A Installing 3rd Party Software 10 Installing Citrix WinFrame Software on the CommPlete 10 Installing Microsoft Windows NT Software on the CommPlete 12 Installing SCO UNIX Software on the CommPlete 13 Installing USL Novell UNIXWare Software on the CommPlete 14 Installing BSD UNIX Software on the CommPlete 15 ...

Страница 10: ...x CommPlete Communications Server ...

Страница 11: ...CommPlete Communications Server 1 1 1 Introduction ...

Страница 12: ...ator Key Features Four independent segments for any combination of T1 Starter or PRI Starter segment kits Data bus eliminates serial cables Ethernet bus reduces network cables to one T1 bus works with T1 card to eliminate the need for a channel bank Control bus delivers management reporting and control information to the controller Side venting cooling fans and a heat sensor with built in reportin...

Страница 13: ...odel Number CC9600 Number of Slots 16 Number of Fans 6 External Connectors Two AC power receptacles Environmental Temperature range 0 40 C 32 104 F Humidity range 0 95 noncondensing Dimensions 31 1 48 3 36 8 cm 12 25 19 14 5 in H W D Weight 11 kg 25 lb Limited Warranty Two years ...

Страница 14: ...CC9600 Chassis User Guide 4 CommPlete Communications Server ...

Страница 15: ...CommPlete Communications Server 5 2 Installation ...

Страница 16: ...Consult the manuals for your other components PS9600 MR9600 MTRAS96 and MTxxxxHD8 before they are installed into the CC9600 To reduce emissions be sure to use blanking plates to cover empty slots in the CC9600 chassis Only connect like circuits In other words connect SELV Secondary Extra Low Voltage circuits to SELV circuits and TN Telecommunications Network circuits to TN circuits Power Supply Po...

Страница 17: ... hazardous condition such as loading heavy equipment in the rack unevenly When connecting the equipment to the supply circuit be sure to check equipment nameplate ratings to avoid overloading ciruits which may cause damage to over current protection devices and supply wiring Be sure to maintain reliable earthing for rack mounted equipment Pay particular attention to supply connections other than d...

Страница 18: ...l power from the chassis The power supplies are connected in parallel so that both power supplies supply power to all power busses in the chassis To remove all power from the left power supply disconnect the left power cord to remove all power from the right power supply disconnect the right power cord 10BaseT Ethernet connector to external concentrator SELV 10Base T Ethernet connector to server N...

Страница 19: ...CommPlete Communications Server 9 Appendix ...

Страница 20: ...I608 driver disk to the root directory of the CommPlete s hard drive 4 Install any software that you need which requires the CD ROM drive or the floppy drive 5 Remove the IDE CD ROM from the system At the main menu select Winframe setup Under Options select Add Remove SCSI devices Highlight IDE CD ROM drive and click on Remove 6 At the Control panel select Devices Highlight the atdisk device Selec...

Страница 21: ...0 for the IRQ for the first card Enter I O address 220 and IRQ 11 for the second card Enter I O address 230 and IRQ 12 for the third card 17 Leave the port numbers at the default settings unless you have a good reason to change them 18 Start setting up your WinStations refer to the Citrix WinFrame documentation ...

Страница 22: ...k on Remove 6 At the Control panel select Devices Highlight the atdisk device Select the Startup button and click on BOOT This will put a circle in the boot section 7 Exit the menus and shutdown the CommPlete system 8 Remove the RASCard MT3334HD8 modems and remove the DA9600 card and cables 9 Re install the RASCard and MT3334HD8 modem cards 10 Restart the CommPlete system 11 Install the ISI608 dri...

Страница 23: ...SCO UNIX Software on the CommPlete This procedure steps you through the process of installing SCO UNIX software from The Santa Cruz Operation Inc on the CommPlete system This procedure can be performed only by using the optional DA96002 load card Procedure to be added at a later date ...

Страница 24: ...L Novell UNIXWare Software on the CommPlete This procedure steps you through the process of installing UNIXWare software from USL Novell on the CommPlete system This procedure can be performed only by using the optional DA96002 load card Procedure to be added at a later date ...

Страница 25: ...UNIX Software on the CommPlete This procedure steps you through the process of installing BSD UNIX software from the University of California Berkely on the CommPlete system This procedure can be performed only by using the optional DA96002 load card Procedure to be added at a later date ...

Страница 26: ...CC9600 Chassis User Guide 16 CommPlete Communications Server ...

Отзывы: